Hearth & Home Technologies 5100I-NL-B User Manual

Page of 44
Page 9
5100-I  ACT WOOD INSERT
438-0380D
September 1, 2008
In Canada a full length 6 inch (15mm) ULC S65 flue 
liner required as per ULC S68.
NOTE:  When installing into a masonry fireplace, the fire-
place must be built to UBC Chapter  standards.  Do not 
remove brick or mortar from masonry fireplace to accom-
modate  insert.    The  permanent  metal  warning  plate  pro-
vided must be attached to the back of the fireplace stating 
the fireplace may have been altered to accommodate the 
insert and must be returned to original condition for use as
a conventional fireplace.
Hearth Extension 
A
B
C
F
E
Insert
SideW
all 
Fascia or Trim 
Mantel 
D
Maximum Mantel Depth: 12 inches (305mm)
 
D
INSTALLATION:   Masonry, Heat Circulating and *Zero Clearance
  12" (305) 
40" (1016) 
35" (889) 
7" (178) 
16" (406) 
8" (200) 
 
 
18" (450) Canada
With 8" Mantel Deflector, Part No. 831-1530
  12" (305) 
27" (686) 
16" (406) 
7" (178) 
16" (406) 
8" (200) 
 
 
18" (450) Canada
Maximum Mantel Depth: 12 inches (305mm)
*Zero Clearance in USA Only.
B.  Clearance to Combustibles
NOTE:  Clearances  may  only  be  reduced  by  means 
approved by the regulatory authority having jurisdiction.
C.  Optional Mantel Deflector
Optional  mantel  deflectors  may  be  purchased  from  your 
dealer to reduce clearances to a mantel. An 8 inch (203mm)
deflector allows a reduction down to  inches (686mm).  
-ANTEL
Figure 9.1
•  Comply  with  all  minimum  clearances  to
combustibles as specified. 
•  Failure to comply may cause fire.
WARNING
Fire Risk.