Hearth & Home Technologies 4100I-GD-B User Manual

Page of 28
Page 15
 
September 1, 2008
4100-I  ACT WOOD INSERT
250-7201E
R
BLOWER CORD LOCATION & BLOWER 
CONTROL BOX WITH SWITCH
Remove Bolt
Remove Bolt
Remove 4 screws, lift 
motor from housing
This  insert  comes  standard  with  a  blower,  installed  at  the 
factory with blower cord on right side of insert (as you face 
the unit).  The blower cord can also be installed on the left 
side.  Disconnect the cord from right side. 
 ROUTE WIRES IN 
FRONT OF FAN
 Re-install on the left side.  Do not route cord 
behind the cooling fan.
Figure 15B - Right Side location
FAN (BlOWER) REPlACEMENT 
included in Kit:  Replacement Blower
Tools Needed:  5-2 Wrench and Phillips Head Screwdriver.
1.  Remove bolts from both sides of the insert and slide the 
lower cast cover towards you. 
See Figure 15D
2.  Loosen  4  screws  (2  on  each  side  of  the  motor)  that 
secures motor to the housing.  Remove the motor.  
See 
Figure 15E.
.  Attach new motor using the same screws to the blower 
housing.
4.  Re-attach  lower  cast  cover  to  insert  using  the  bolts 
removed in Step 1. 
Figure 15E
Figure 15D
Black
Red
White
Snap Disc
Blower Control 
Box with Switch
Cooling Fan
Black
HIGH  OFF 
LOW 
FAN 
AUTO 
MANUAL 
MANUAL: Over-rides 
the internal Snap Disc 
AUTO:  Fan will 
turn ON/OFF 
automatically and 
is controlled by the 
internal Snap Disc 
Figure 15A
Operating the Blower Control Box with Switch
1.  The blower will turn on/off automatically when set to AUTO.
2.  When set to MANUAL, the fan will turn on/off only when you 
turn  it  on  or  off.   This  setting  over-rides  the  internal  snap 
disc.
.  Adjust the speed of the fan by turning the HIGH/LOW knob 
to the desired setting. 
Black
Red
White
Snap Disc
Cooling Fan
Figure 15C - left Side location