Initial Installation
E
LECTRICAL
 R
EQUIREMENTS
:
The ENVIRO ASCOT will operate without electrical power. This model has a millivolt gas control, which 
uses the pilot flame to generate enough electricity to operate the main burners. The appliance when 
equipped with an optional blower must be electrically connected and grounded in accordance with local 
codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 
1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI 
/ NFPA 70 in the U.S.
WARNING: Electrical grounding instructions. This appliance is equipped with a three-prong (grounding) 
plug for your protection against shock hazard, and should be plugged directly into a properly grounded 
I
NSTALLATION
 
OF
 O
PTIONAL
 B
LOWER
:
COOL / HEAT
PROGRAM
DOWN
UP
70 ° F
Blue
Purple
Gas Control
Valve
Thermopile
ON/OFF/Thermostat
Grey
Optional
Thermostat
Pilo
Adjustment
Screw
���
�����
�����
���
�����������
������
�����
�����
���
����������
����� ������
Remove  the  pre-assembled  blower  from  the 
packaging. Inspect the blower for damage. If 
damage is noticed call your dealer, distributor 
or  courier  company  and  have  components 
replaced.
Place  the  fan  assembly  behind  the  unit  and 
secure  with  the  two  screws  provided  (as 
shown in Figure 31).
Remove the fan controller, mounting box and 
install  fan  controller.  Neatly  dress  the  wires 
from the fan assembly to the fan controller.
Install  the  fan  temperature  sensor  with  the 
two (2) screws provided.
Plug the fan assembly into the wall outlet and 
turn the unit on to ensure fan operation.
���� � ���� ��
��� �����������
������
������ ������
��� ����������
��� �����������
������ ������
�������� ���
Figure 31: Optional Fan Kit Installation.
Figure 30.  Wiring Diagram For Fan Control.
Figure 29.  Wiring Diagram For Gas Valve.
Table 4.  Recommended Thermostat Wire Size.
Wire Size
Max. Length
14 gauge
100 ft  (30.48 m)
16 gauge
60 ft   (18.29 m)
18 gauge
40 ft   (12.00 m)
20 gauge
25 ft   (7.62 m)
22 gauge
18 ft   (5.49 m)
three-prong outlet.  DO NOT cut or remove the grounding prong 
from this plug.
CAUTION: Label all wires prior to disconnection when servicing 
controls.  Wiring  errors  can  cause  improper  and  dangerous 
operation. Verify proper operation after servicing.