Maintenance And Service
R
OUTINE
 M
AINTENANCE
:
At least once a year, run through the following procedures to ensure the system is clean and working 
properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not 
blocked by anything. The pilot flame should be blue with little or no yellow on the tips.
Warning: Clearances must be sufficient to allow access for maintenance and service
Warning:  Failure  to  position  the  parts  in  accordance  with  this  manual,  or  failure  to  use  only  parts 
specifically approved with this appliance may result in property damage or personal injury.
The venting system must be periodically examined; it is recommended the examination is done by a 
qualified agency. 
C
LEANING
 T
HE
 G
LASS
:
When the fireplace has cooled, remove the face of the fireplace along with the glass. See M
AINTENANCE
 
A
ND
 S
ERVICE
 - G
LASS
 D
OOR
 R
EMOVAL
. Check the gasket material on the back of the glass, making sure that it 
is attached and intact.  
It  will  be  necessary  to  clean  the  ceramic  glass  periodically. During a  cold  start  up,  condensation  will 
sometimes form on the glass. This is a normal condition with all fireplaces. However, this condensation 
can allow dust and lint to cling to the glass surface.  Initial paint curing of the appliance can leave a slight 
film behind the glass, a temporary problem.  The glass will need cleaning initially after the first 4 hours 
of use and again about two (2) weeks after installation. Use a mild glass cleaner and a soft cloth
abrasive cleaners will damage the glass and enamal surfaces. Depending on the amount of use, 
the glass should require cleaning no more than two or three times a season. Do not clean the glass 
when it is hot.
C
LEANING
 T
HE
 F
IREBOX
:
Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and 
place on a paper towel. Vacuum the bottom of the firebox thoroughly. Carefully clean any dust off the 
logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or 
severe warping. If a problem is suspected, contact the dealer. Check the logs for deterioration or large 
amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers 
as in the L
OG
 S
ET
 
AND
 E
MBER
 I
NSTALLATION
 section. If new/more embers and rock wool are required, contact 
your nearest ENVIRO dealer. 
C
HANGE
 B
ATTERY
 
IN
 I
GNITION
 M
ODULE
:
If the unit does not spark when lighting, the battery in the electronic ignition could need replacing.
The ignition module is located at the far left behind the valve cover (see Figure 6).  Remove the battery 
cover, located on the left side of the module, and replace the AA battery.
Reinstall  the  battery  cover  and  check  for  spark  by  depressing  the  pilot  knob  located  on  the  control 
panel.