10. Apply a bead of Mill-Pac Black sealant to 
the top section of the Ø4” (10 cm) by 5” 
(12.5 cm) flue collar adaptor previously 
installed  into  the  fireplace  flue  outlet.  
Slide  the  Ø4”  (10  cm)  flex  vent  over 
the flue collar and secure with three (3) 
sheet metal screws evenly spaced.
11. Place  a  bead  of  high  temperature 
silicone  on  the  intake  collar  of  the 
fireplace,  slide  the  Ø6⅝”  (16.25  cm) 
flex intake liner over the collar, secure 
the flex liner with three (3) sheet metal 
screws evenly spaced.
12. On  the  outside  of  the  exterior  wall, 
apply  a  bead  of  Mill-Pac  Black  sealant 
to  the  Ø4”  (10  cm)  pipe  of  the  vent 
terminal.    Slide  the  flex  liner  onto  the 
vent terminal and secure with three (3) 
sheet metal screws evenly spaced.
13. Place  a  bead  of  high  temperature 
silicone on the intake collar of the vent 
terminal,  slide  the  Ø6⅝”  (16.25  cm) 
flex intake liner over the collar, secure 
the flex liner with three (3) sheet metal 
screws evenly spaced.
14. Attach the vent terminal to the outside of the house using four (4) wood screws provided. 
15. Light the appliance and ensure proper operation.
o
theR
 a
PPRoveD
 v
ent
 P
aRts
:
Table 4: Approved Vent Manufacturers
Manufacturer
Trade Name
Nominal Sizes
American Metal Products
AmeriVent Direct
4” - 6 5/8”
Security Chimneys International LTD
Secure Vent
4” - 6 5/8”
Selkirk Metalbestos
Direct-Temp
4” - 6 5/8”
Simpson Dura-Vent
Direct Vent GS
4” - 6 5/8”
The  Westport  fireplace  has  been  tested  and  certified  for  use  with  AMERICAN  METAL  PRODUCTS 
“AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES.  SECURITY CHIMNEY’S 
“SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available 
for  horizontal  and  vertical  venting.    When  using  Simpson  Duravent,  it  is  recommended  that,  before 
installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-
Pac to each inner joint.  When planning an installation, it will be necessary to select the proper length of 
vent pipe for the particular requirements.  
WARNING: Do not mix parts from different vent manufacturers’ systems.