Enviro Haven Direct Vent Fireplace User Manual

Page of 41
Initial Installation
QUALIFIED INSTALLERS ONLY
The framing boards may touch the top, side and back standoffs, but no insulation or other material 
can be placed between the frame and the standoffs.
The  gas  line,  3⁄8  inch  NPT,  can  be  brought  to  either  the  right  side,  the  left  side,  or  the  bottom  of 
the  fireplace.  If  this  set  up  is  inconvenient,  the  electrical  wire  and  the  gas  line  configuration  can  be 
reversed. 
The location should be chosen so the fireplace must be at least 36 inches (91.4 cm) from drapes, doors 
and other combustibles. The framed opening should also be a minimum of 3.5 inches (8.9 cm) from the 
nearest perpendicular wall (sidewall to the edge of the opening).
The HAVEN is designed so it can be installed at floor level without a required hearth
.
C
ORNER
 I
NSTALLATION
:
R
AISED
 F
IREPLACES
 
AND
 H
EARTHS
:
Even though the Haven can be installed at floor level without a hearth, there are a few options with raised 
fireplaces: raised with a floor level hearth (Figure 17), raised with a raised hearth (Figure 18), or raised 
with no hearth (Figure 19). If the fireplace is raised, it cannot be placed within 18 inches (45.7cm) of the 
ceiling. When installing a raised fireplace, it is imperative that the support stand is strong enough to hold 
the weight of the fireplace (up to 140lb [63.5Kg]) and venting.
Figure 16.  Dimensions for a corner installation.
2" x 6"
Stud
1
/
2
" (13mm)
Front Facing
18
15
/
16
"
(481mm)
30
5
/
16
"
(770mm)
21
7
/
16
"
(545mm)
6
3
/
8
"
(162mm)
The  dimensions  for  installing  a 
fireplace in the corner of a room 
are  given  in  Figures  16.  Refer 
to  “I
NITIAL
  I
NSTALLATION
  -  V
ENT
 
C
ONFIGURATIONS
 
AND
  R
ESTRICTOR
 
S
ETTINGS
”  for  allowable  pipe 
lengths. 
Do  not  interfere  with  the 
structural integrity of the walls.
14