Enviro Haven Direct Vent Fireplace User Manual

Page of 41
2. Start the pilot by pressing the gas control knob and turning it to PILOT.  
While holding the gas control knob in, press the piezo ignitor several times 
until the pilot light starts. Hold the gas control knob in for 30 seconds. 
Check that the pilot has fully engulfed the thermocouple assembly (see 
Figure 3).
3. Start the main burner by turning the gas control knob to ON and then 
turn the rocker switch to ON. Check that all burner ports have flame.
4. Leak test all gas joints again.
A
IR
 S
HUTTER
:
The air shutter adjustment lever is above the left side of the control valve (see Figure 4).
The air shutter allows the amount of air coming into the fireplace to be adjusted in order to accommodate 
different altitudes and venting arrangements. Start the pilot and then the burner. Make sure the pilot 
flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly 
fifteen minutes and then examine the flames, compare the flames to Figure 56.
The ideal flame will be blue at the base and light orange above. The flames should be of medium height. 
If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, 
Open/
More Air
Close/
Less Air
Air Shutter
the fireplace is getting too much air. Therefore, 
the  air  shutter  should  be  closed  (moved  right) 
slightly  until  the  correct  flames  are  achieved.  
Flames  that  are  very  orange,  with  tall,  dark, 
stringy  tips,  are  not  getting  enough  air.  Open 
(move left) the venturi until the flames clean up. 
If the venturi is opened, or closed all the way, and 
the  correct  flames  cannot  be  attained,  turn  off 
the gas and contact your dealer.
Warning:  Incorrect  venturi  adjustment  may 
lead  to  improper  combustion,  which  could  be  a 
safety hazard. Contact your dealer if there is any 
concern about the venturi adjustment.
Figure 4.  Air shutter adjustment lever.
����������
������������
Figure 3.  Pilot Flame
7
Operating Instructions
P
ILOT
 L
IGHT
:
1. Turn off the gas to the fireplace.  If not recently done, remove the glass and let the unit air 
out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints 
with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING. 
B
LOWER
 
SPEED
:
The blower will come on only when the fireplace is up to temperature (approximately 20 minutes).  The 
speed of the fan can be changed by turning the fan control knob.  To turn the blower off, turn the knob 
COUNTER CLOCKWISE until it “clicks” off  (Figure 5). 
It is advisable not to operate the blower below 
1
/
3
 speed as it puts a strain on the windings of the blower 
and running the blower at lower speeds could also cause premature fan failure.