    Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
A.  Congratulations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
B.  Limited Lifetime Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .  5
1 Listing and Code Approvals 
 
A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
B.  Tempered Glass Specifi cations  . . . . . . . . . . . . . . . . . . . . .  7
C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
D.  High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . .  7
E.  Non-Combustible Materials Specifi cation. . . . . . . . . . . . . .  7
F.  Combustible Materials Specifi cation  . . . . . . . . . . . . . . . . .  7
G.  Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
H.  Requirements for the Commonwealth of Massachusetts . .  8
User Guide
2 Operating Instructions 
 
A.  Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
B.  Your Fireplace  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
C.  Fan Kit (optional)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
D.  Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
E.  Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . .  10
F.  Fixed Glass Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
G.  Remote Controls, Wall Controls and Wall Switches . . . . .  10
H.  Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . .  10
I.  Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . .  11
J.  After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
K.  Frequently Asked Questions  . . . . . . . . . . . . . . . . . . . . . .  12
3 Maintenance and Service 
 
A.  Maintenance Tasks-Homeowner  . . . . . . . . . . . . . . . . . . .  13
B. Maintenance Tasks-Qualifi ed Service Technician  . . . . . .  14
Installer Guide
4 Getting Started 
 
A.  Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . .  16
B.  Design and Installation Considerations  . . . . . . . . . . . . . .  17
C.  Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . .  17
D.  Inspect Appliance and Components . . . . . . . . . . . . . . . . .  17
5 Framing and Clearances 
 
A.  Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . .  18
B.  Constructing the Appliance Chase . . . . . . . . . . . . . . . . . .  19
C.  Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19
D.  Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . .  20
6 Termination Locations 
 
A.  Vent Termination Minimum Clearances . . . . . . . . . . . . . .  21
7 Vent Information and Diagrams 
 
A.  Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
B.  Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
C.  Use of Elbows  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
D.  Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
E.  Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24
8 Vent Clearances and Framing 
 
A.  Pipe Clearances to Combustibles  . . . . . . . . . . . . . . . . . .  28
B.  Wall Penetration Framing . . . . . . . . . . . . . . . . . . . . . . . . .  29
C.  Install the Ceiling Firestop  . . . . . . . . . . . . . . . . . . . . . . . .  30
D.  Install Attic Insulation Shield . . . . . . . . . . . . . . . . . . . . . . .  31
9 Appliance Preparation 
 
A.  Attaching Sheetrock Ledges  . . . . . . . . . . . . . . . . . . . . . .  32
B. Temporary Access Panel . . . . . . . . . . . . . . . . . . . . . . . . . .  32
C.  Securing and Leveling the Appliance . . . . . . . . . . . . . . . .  33
D.  Installing the Fiberglass Gasket . . . . . . . . . . . . . . . . . . . .  33
10 Installing Vent Pipe 
 
A.  Assemble Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . .  34
B.  Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . .  35
C.  Secure the Vent Sections . . . . . . . . . . . . . . . . . . . . . . . . .  35
D.  Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . .  36
E.  Install Metal Roof Flashing . . . . . . . . . . . . . . . . . . . . . . . .  37
F.  Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . .  37
G.  Install RF4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38
H.  Install Vertical Termination Cap  . . . . . . . . . . . . . . . . . . . .  39
I.  Heat Shield Requirements for Horizontal Termination . . .  39
J.  Install Horizontal Termination Cap . . . . . . . . . . . . . . . . . .  40
11 Gas Information 
 
A.  Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  41
B.  Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  41
C.  Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  41
D.  High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . .  41
12 Electrical Information 
 
A.  Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . .  42
B. Intellifi re Ignition System Wiring . . . . . . . . . . . . . . . . . . . .  42
C.  Optional Accessories Requirements  . . . . . . . . . . . . . . . .  42
D.  Electrical Service and Repair . . . . . . . . . . . . . . . . . . . . . .  43
E.  Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . .  44
F.  Wall Switch Installation for Fan (Optional) . . . . . . . . . . . .  44