Enviro Ascot User Manual

Page of 40
11
Maintenance And Service
b)  Insert  a 
5
/
32
”  or  4  mm  Allen  wrench  into  the 
hexagonal key-way of the screw (see Figure 8), 
rotate  it  counter-clockwise  until  it  is  free  and 
extract it.
c)  Check  that  the  screw  is  clean  and  if  necessary 
remove dirt.
d)  Flip the screw (refer to Figure 9).
e)  Using  the  Allen  wrench  as  shown  in  Figure  8, 
rotate the screw clockwise until a torque of 9 inch 
lbs. WARNING! Do not over tighten the screw. 
It is recommended that you grip the wrench by 
the short side.
f)  Verify that if the conversion is from NG to LPG, 
the screw must be re-assembled with the red o-
ring visible (refer to Figure 10). If the conversion 
is from LPG to NG, the red o-ring of the screw 
must be not visible.
Figure 9: Flip valve 
screw.
g)  Re-attach  the  black  protection 
cap  that  was  removed  in  step  a 
(Figure 7).
8.  Reinstall  the  burner,  brick  panels, 
log  set,  embers,  and  glass  door. 
Also  refer  to  S
ECONDARY
  I
NSTALLATION
 
- I
NSTALLING
 L
OG
 S
ET
 
AND
 E
MBERS
. When 
re-installing the burner, ensure that 
the burner to pilot hood relationship 
Figure 10: O-ring on valve screw.
is similar to what is shown in Figure 11. On some units you will need to pay 
special attention when installing the burner that the venturi adjustment rod 
is properly installed into the venturi adjustment piece welded to the burner 
venturi tube
9.  Reconnect the main gas line if it was disconnected and open the shut-off valve 
at the gas line to the unit.
10.  Use a small brush to apply a warm soapy water solution to all gas connections 
(use a half dish soap and half warm water). If a gas leak is present, bubbling 
will occur. Gas leaks can be repaired by using an approved pipe thread sealant 
or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN TESTING FOR 
LEAKS.
Figure 8: Removing valve screw.
7.  Convert the SIT gas valve:
a)  Remove the black protection cap from the HI/LO knob by hand shown in Figure 7.
Figure 11. Ignitor 
assembly beside the 
burner.
11.  Reconnect the electrical power to the unit.
12.  Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and 
operation  and  proper  flame  appearance.  Also  refer  to  S
ECONDARY
  I
NSTALLATION
  -  L
OG
  S
ET
 
AND
  E
MBERS
 
I
NSTALLATION
 for a flame appearance picture. 
13.  MAKE SURE that the conversion label is installed on or close to the rating label to signify that the 
unit has been converted to a different fuel type.