Initial Installation
QUALIFIED INSTALLERS ONLY
18
����
�������
Figure 25: Wire Spacers.
it  to  the  inner  wall  frame  using  four  (4)  11⁄2”  wood  screws.    If  a  wall  is 
greater than 8” (203mm) in depth, the clearance above the flex must be 
43⁄8” (111mm)
6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5 
cm) provided flue collar adaptor.  Press the flue collar into the flue outlet of 
the fireplace so that the Mill-Pac seals the flue collar to the flue outlet.  
7. Stretch both the Ø4” (10 cm) flex vent and the Ø65⁄8” (16.25 cm) flex intake 
liner to the length needed to ensure the flex can be easily connected to the 
Figure 26: Wire Spacer in Place.
vent terminal.
8. Slide the Ø65⁄8” (16.25 cm) flex intake liner 
over  the  flex  vent.  Install  four  (4)  wire 
spacers  around  the  flex  pipe.  Ensure  the 
wire spacers are positioned at either end of 
the pipes, and at each end of any elbows in 
the liners (refer to Figure 25 and 26).
9.   Install  the  flex  pipe  assembly  through 
the  wall thimble, ensure  that  this portion 
of  pipe  slides  through  the  outside  wall 
far  enough  to  connect  onto  the  vent 
termination cap.
KIT COMPONENTS:
Qnty
Description
Qnty
Description
1
Horizontal direct vent termination cap
4
Wire spacers
1
Flue collar adapter
1
4 oz tube Mill-Pac Sealant
1
Wall thimble
1
4 oz tube RTV silicone
1
5’  (190 cm) length of Ø4” (10 cm) double walled flex pipe
12
9/16” tech screws
1
5’  (190 cm) length of Ø65⁄8” (16.8 cm) double walled flex pipe
8
11⁄2” wood screws
Please  ensure  that  all  components  are  supplied  with  this  kit.  If  components  are  missing  or  have 
been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if 
components are missing or damaged.
INSTALLATION INSTRUCTIONS:
1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet 
the clearances noted in the venting section, and any or all local code requirements. 
2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing 
pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location 
should be adjusted if obstructions are found in the wall.
3. Project a line from the center point of the flue outlet upward and outward to the desired flue outlet 
location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall. 
Cut the hole from the interior through the exterior wall surfaces.
4. Frame the hole as shown in Figure 29.
5. Trim the wall thimble to match the wall thickness as necessary.  Install the wall thimble and secure 
Please read and understand these instructions before installing. Failure to follow 
these instructions carefully could cause property damage or personal injury.
F
IREPLACE
 H
ORIZONTAL
 V
ENT
 K
IT
 50-1235: