Figure 23: Vent restrictor ring.
Figure 22. Possible Vent Configurations; Vertical 
and Horizontal Terminations.
V
ENT
 C
ONFIGURATIONS
:
Figures 22 shows the range of venting options, it shows 
possible vent configurations if the unit is top vented, 
for vertical and horizontal terminations, any layout that 
remains within the shaded area is acceptable. Having 
the fewest number of elbows is ideal, as they tend to 
disrupt air movement. Using 45˚ elbows is preferable 
to using 90˚ elbows. Also, a shorter vent system will 
perform better than a longer one.
NOTE:  The  total  length  of  the  vent  pipes  can  not 
exceed 33 ft (10.1 m). Any combination of rise and run 
can be used as long as it lays within the shaded area 
(a total of three (3) 90° elbows or six (6) 45° elbows 
can be used). In addition to what is shown, if a 90° 
elbow is used in the horizontal plane, 3 ft (91.4 cm) 
must be subtracted from the allowable horizontal run 
(for each 45° elbow, 11⁄2 ft must be subtracted from 
the allowable horizontal run). 
V
ENT
 R
ESTRICTOR
 R
ING
:
A vent restrictor ring is supplied with each direct vent fireplace. 
This restrictor ring is to be installed when the vertical chimney 
installation is over 6 ft (1.83 m). Before the chimney is placed 
onto the stove, place this vent restrictor ring into the 4 inch 
(10.2 cm) flue pipe (as shown), once the vent restrictor ring 
has  been  installed,  the  vertical  sections  of  chimney  can  be 
installed.