VENT TERMINAL CLEARANCES 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 3 
A= Clearance above grade, verandah, porch, deck, or 
 
[balcony (*12 inches (30cm) minimum] 
B= Clearance to window or door that may be opened   [*12 
inches (30cm) minimum] 
C= Clearance to permanently closed window 
 
[minimum 12 inches (30cm) recommended to 
 
prevent condensation on window] 
D= Vertical clearance to ventilated soffit located 
 
above the terminal within a horizontal 
 
distance of 2 feet (60cm) from the center-line 
 
of the terminal 24 inches ( 60cm) minimum 
E= Clearance to unventilated soffit  
[18 inches   (45cm) minimum] 
F= Clearance to outside corner [12 inches minimum] 
G= Clearance to inside corner [`12 inches minimum] 
H= *Not to be installed above a meter/regulator 
 
assembly within 3 feet (90cm) horizontally   from 
the center-line of the regulator 
I= Clearance to service regulator vent outlet  
[*6 feet     (1.8m) minimum] 
J= Clearance to non-mechanical air supply inlet to 
 
building or the combustion air inlet to any 
 
other appliance [12 inches (30cm) minimum] 
K= Clearance to a mechanical air supply inlet  
[*6   feet (1.8m) minimum] 
L= *** Clearance above paved side-walk or paved 
 
driveway located on public property  
[*7 feet      (2.1m) minimum] 
M= Clearance under verandah, porch, deck, or 
 
balcony [*24 inches (60cm) minimum **] 
 
*** A vent shall not terminate directly above a  sidewalk or paved driveway, which is located between two single family dwellings and serves 
both dwellings.  
**  Only permitted if verandah, porch, deck, or balcony, is fully open on a minimum of 2 sides beneath the floor 
• 
As specified in CGA B149 Installation Codes (1991) Note: Local Codes or Regulations may require different clearances 
 
 