Enviro C-10794 User Manual

Page of 45
15
Initial Installation
QUALIFIED INSTALLERS ONLY
P
LANNING
 Y
OUR
 I
NSTALLATION
:
When planning your installation, it will be necessary to select the proper length of vent pipe for your 
particular requirements. It is important to note when passing through a wall, the maximum allowable 
wall thickness is 10 inches (25.4 cm), 11⁄2 inches (3.8 cm) clearance to combustibles must be maintained. 
Select  the  amount  of  vertical  rise  desired  for  “vertical-to-horizontal”  type  installations.  To  determine 
the length of vent pipe required for vertical installations, measure the distance from the appliance flue 
outlet to the ceiling, the ceiling thickness, the vertical rise through the attic or second story, and allow 
Vertical
Termination
Storm Collar
Flashing
Round Support
Box/Wall Thimble
Ceiling Firestop
Pipelength
Pipelength
Cathedral Ceiling
Support Box
Pipelength
Round Support
Box/Wall Thimble
Pipelength
Horizontal
Termination
90° Elbow
for sufficient vent height above the roof line. For two 
story applications, a fire stop is required at each floor 
level. If an offset is needed in the attic, additional pipe 
and  elbows  will  be  required.  To  connect  the  venting 
system to the appliance flue outlet, a twist-lock adapter 
is built into the appliance at the factory. Refer to ‘Vent 
Configuration  and  Restrictor  Settings’  for  venting 
parameters.
Your total vent pipe length must be within the shaded 
area  of  Figure  12.  If  a  90°  elbow  is  used  in  the 
horizontal  plane,  36”  (91.4  cm)  must  be  subtracted 
from the allowable horizontal run. 
There are three (3) basic types of Direct Vent System 
installations.  The  three  (3)  types  of  installations  are 
shown in Figures 13 through 15.
Figure 13: Common Horizontal Installation.
Figure 14: Common Vertical Installation.
Round Support
Box/Wall Thimble
2 ft (610 mm)
Pipelength
36" (915 mm)
Snorkel
45° Elbow
Figure 15: Common Snorkel Installation.