Enviro C-10794 User Manual

Page of 45
25
Initial Installation
QUALIFIED INSTALLERS ONLY
V
ENTING
 
INTO
 
A
 C
LASS
 ‘A’ C
HIMNEY
:
This model is also certified and tested to vent into CLASS 
‘A’ wood stove chimneys.
Place  the  freestanding  direct  vent  appliance  in  the 
desired location.
Use a conversion kit from Simpson Duravent (931, 932, 
or  933),  or  Security  Chimney  (SV4CCK1,  SV4CCK2,  or 
SV4CCK1). Which kit is used will depending on the inner 
diameter of the CLASS ‘A’ chimney that this appliance is 
to be vented into.
Place a bead of high temperature silicone or mil-pac at 
each connection to ensure a tight seal.
NOTE: An approved 4” (10 cm) diameter flex liner must 
be used in the application.
NOTE:  Use  Simpson  Dura  Vent  from  the  top  of  the 
appliance until this vent reaches the CLASS ‘A’ chimney. 
Install the retro adapter to the top section of GS direct 
vent pipe and install the flex liner to the retro adapter. 
Fully line the CLASS ‘A’ chimney with a minimum 4” (10 
cm) flex liner to the top of the CLASS ‘A’ chimney.
Place a bead of high temperature silicone to the Simpson 
Cap  adapter  and  securely  attach  the  flex  liner  to  the 
adapter.
Secure  the  cap  adapter  to  the  CLASS  ‘A’  chimney 
ensuring an airtight seal.
Install the vertical termination cap.
Light the unit and ensure proper operation.
THE USE OF ANY EXISTING CHIMNEY AS AN AIR INTAKE 
IS NOT COVERED UNDER THE ANSI Z21.88-2002 CSA 
2.33a-2002 TEST METHODS AND THE RESULTING ITS/
WH PRODUCT CERTIFICATION. THE CODE AUTHORITY 
HAVING  JURISDICTION  MUST  BE  CONSULTED  PRIOR 
TO PROCEEDING WITH THIS INSTALLATION METHOD.
Figure 33: Assembly of Venting into a Class ‘A’ 
Chimney.