Fan assembly
Valve cover
Control panel
(Fan control location)
Screw hole
Figure 47: Optional Blower (Fan) Installation.
Secondary Installation
I
NSTALLATION
 
OF
 O
PTIONAL
 B
LOWER
:
1. Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is 
noticed call your dealer, distributor or courier company and have components replaced.
2.  Ensure  the  temperature  sensor  will  touch  the 
unit when mounted. If it does not touch, adjust 
the sensor so it does.
2.  Place  the  fan  assembly  behind  the  unit  and 
secure  with  the  three  screws  provided,  (as 
shown in Figure 47). 
3. Open the gas valve cover. Carefully cut the decal 
portion on the control panel and install the fan 
control switch in this location. See Figure 46 for 
wiring of optional blower.
4. Plug the fan assembly into the wall outlet and 
turn the unit on to ensure fan operation.
33
I
NSTALLATION
 
OF
 L
OG
 S
ET
 
AND
 E
MBERS
:
The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” 
and will not burn correctly.  The burner come with four (4) locator pins, and the right log has two (2) 
ledges which make alignment easier. Using the pictures provided, carefully set the logs in place.
Figure 48: Step 1 of Log Placement.
Figure 49: Step 2 of Log Placement.
NOTE: The logs are fragile and 
should be handled gently.
CAUTION: Use only the type of 
ember material supplied with this 
appliance.  Due  to  the  irregular 
size  of  the  ember  material  there 
may be more than required. The 
use of other foreign materials on 
the burners may create dangerous 
conditions.
If over time, through cleaning and 
servicing,  these  embers  require 
replacement, contact the nearest 
ENVIRO  dealer  for  replacement 
embers.