Enviro C-10794 User Manual

Page of 45
36
Figure 57: Top brick panel in place, screws shown.
Figure 58: Back brick panel in place.
Figure 59: Side brick panels in place.
Figure 56: Brick panel  bracket, slots shown.
1. Remove the two (2) screws from the 
rear  of  the  baffle,  use  a  1⁄4”  socket 
or  a  flat  head  screwdriver.  Place  the 
provided brick bracket (Figure 56) at 
the  rear  of  the  baffle  with  the  slots 
over the screw holes (see Figure 57). 
Insert two (2) of the provided screws 
into  the  two  (2)  holes  along  the 
bottom of the baffle.
2.  Remove  the  two  (2)  screws  from  the  front  of  the 
baffle.  Slide  the  top  brick  panel  into  the  bottom 
bracket and place the other brick bracket over the top 
of the panel and line up the slots on the bracket with 
the holes at the top of the baffle. Use two (2) of the 
provided screws to hold the bracket in place. Ensure 
the top panel is centered before tightening the four 
(4) screws completely (refer to Figure 57).
3. Slide the bottom brick panel into place under/behind 
the top panel bracket, the notched side is to rest on 
the firebox bottom. The panel should rest flush with 
the back of the firebox (refer to Figure 58).
4. Slide each side brick panel into place along the sides 
of the firebox. The panels should rest flush with the 
back  panel  and  the  sides  of  the  firebox  (refer  to 
Figure 59).
Secondary Installation
I
NSTALLATION
 
OF
 P
ANEL
 S
ET
:
Do not install when the unit is hot.
The  brick  panel  set  is  fragile.  Handle  panels  with  care  and  avoid  knocking  them  on  the 
placement pins or any other object.