Enviro C-10794 User Manual

Page of 45
5
Specifications
WARNING: 
Operation of this heater when not connected to a properly installed and maintained venting system can 
result in carbon monoxide (CO) poisoning and possible death.
D
IMENSIONS
:
16
5
/
8
"
(42.2cm)
25 3⁄4"
(65.3cm)
25 3⁄4"
(65.4cm)
27"
(68.6cm)
25 3⁄4"
(65.3cm)
17
1
/
8
"
(43.5cm)
15 3⁄4"
(40.0cm)
27"
(68.5cm)
15
1
/
8
"
(39.0cm)
Floor to center of flue
REAR VENT
231⁄2” (59.7 cm)
C
LEARANCES
 
TO
 C
OMBUSTIBLES
:
A. Sidewall to unit 
11 inches   (27.9 cm)   
 
 
B. Backwall to unit 
2.5 inches  (6.35 cm)  
 
 
C. Corner to unit 
2.5 inches  (6.35 cm)  
 
 
D. Ceiling      
60 inches above floor (152.4 cm) 
 
E. Floor         
(hard wood and linoleum) 0 inches
Note:  When  installing  on  a  carpeted  surfaces  a  non- 
combustible hearth pad must be used.
Minimum Alcove Dimensions:
 
Width  
 
48 inches (121.9 cm)
 
Height  
 
60 inches (152.4 cm)
 
Depth (max) 
24 inches (60.96 cm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE
Figure 1: Westport Exterior Dimensions.
�����
���� ����
��
��
��
��
�������� ����
��
��
��
Figure 2: Clearances to combustibles.