Enviro ENVIRO User Manual

Page of 42
21
Flue Pipe Adaptor
Wall Framing
Wall Thimble
Fire Stop
Exhaust 4" Flex Pipe
Combusion Air 6 5/8" Flex Pipe
Wire Spacers
Horizontal Vent Termination
9.   Install the flex pipe assembly through the wall thimble, ensure that this portion of pipe slides through 
the outside wall far enough to connect onto the vent termination cap.
10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar 
adaptor previously installed into the fireplace flue outlet.  Slide the Ø4” (10 cm) flex vent over the flue 
collar and secure with three (3) sheet metal screws evenly spaced.
11.  Place  a  bead  of  high  temperature 
silicone  on  the  intake  collar  of  the 
fireplace,  slide  the  Ø65⁄8”  (16.25 
cm) flex intake liner over the collar, 
secure  the  flex  liner  with  three  (3) 
sheet metal screws evenly spaced.
12. On the outside of the exterior wall, 
apply  a  bead  of  Mill-Pac  Black 
sealant to the Ø4” (10 cm) pipe of 
the  vent  terminal.    Slide  the  flex 
liner  onto  the  vent  terminal  and 
secure  with  three  (3)  sheet  metal 
screws evenly spaced.
13.  Place  a  bead  of  high  temperature 
silicone  on  the  intake  collar  of  the 
vent terminal, slide the Ø65⁄8” (16.25 
cm) flex intake liner over the collar, 
secure  the  flex  liner  with  three  (3) 
sheet metal screws evenly spaced.
14.  Attach  the  vent  terminal  to  the 
outside of the house using four (4) 
wood screws provided. 
15. Light  the  appliance  and  ensure 
proper operation.
Figure 33: Installation of Fireplace Horizontal Vent Kit.
Initial Installation
QUALIFIED INSTALLERS ONLY
O
THER
 A
PPROVED
 V
ENT
 P
ARTS
:
Table 5: Approved Vent Manufacturers
Manufacturer
Trade Name
Nominal Sizes
American Metal Products
AmeriVent Direct
4” - 6 5/8”
Security Chimneys International LTD
Secure Vent
4” - 6 5/8”
Selkirk Metalbestos
Direct-Temp
4” - 6 5/8”
Simpson Dura-Vent
Direct Vent GS
4” - 6 5/8”
The Retreat fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT 
DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES.  SECURITY CHIMNEY’S “SECURE VENT 
DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and 
vertical venting.  When using Simpson Duravent, it is recommended that, before installation, a bead of 
RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner 
joint.  When planning an installation, it will be necessary to select the proper length of vent pipe for the 
particular requirements.