Enviro Indoor Gas Fireplace User Manual

Page of 32
12
Maintenance And Service
c)  Check  that  the  screw  is  clean  and  if  necessary 
remove dirt.
d)  Flip the screw (refer to Figure 13).
e)  Using  the  Allen  wrench  as  shown  in  Figure  12, 
rotate the screw clockwise until a torque of 9 inch 
lbs. WARNING! Do not over tighten the screw. 
It is recommended that you grip the wrench by 
the short side.
f)  Verify that if the conversion is from NG to LPG, 
the screw must be re-assembled with the red o-
ring visible (refer to Figure 14). If the conversion 
is from LPG to NG, the red o-ring of the screw 
must be not visible.
g)  Re-attach the black protection cap that was 
removed in step a (Figure 11).
Figure 13: Flip valve 
screw.
8.  Reinstall  the  burner,  brick  panels, 
log set, embers, and glass door. Also 
refer  to  S
ECONDARY
  I
NSTALLATION
  - 
I
NSTALLING
 L
OG
 S
ET
 
AND
 E
MBERS
. When 
re-installing the burner, ensure that 
the burner to pilot hood relationship 
is similar to what is shown in Figure 
15. On some units you will need to 
pay special attention when installing 
Figure 14: O-ring on valve screw.
the burner that the venturi adjustment rod is properly installed into 
the venturi adjustment piece welded to the burner venturi tube
9.  Reconnect  the  main  gas  line  if  it  was  disconnected  and  open  the 
shut-off valve at the gas line to the unit.
10.  Use a small brush to apply a warm soapy water solution to all gas 
connections (use a half dish soap and half warm water). If a gas leak 
is present, bubbling will occur. Gas leaks can be repaired by using an 
approved pipe thread sealant or approved Teflon tape. NEVER USE 
AN OPEN FLAME WHEN TESTING FOR LEAKS.
11.  Reconnect the electrical power to the unit.
Figure 12: Removing valve 
screw.
b)  Insert a 
5
/
32
” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 12), rotate 
it counter-clockwise until it is free and extract it.
12.  Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and 
operation and proper flame appearance. Also refer to S
ECONDARY
 I
NSTALLATION
 - L
OG
 S
ET
 
AND
 E
MBERS
 
I
NSTALLATION
 for a flame appearance picture. 
13.  MAKE SURE that the conversion label is installed on or close to the rating label to signify that the 
unit has been converted to a different fuel type. 
Figure 15: Burner to pilot hood 
relationship.