Enviro Meridian User Manual

Page of 44
2.  Open the right cab side to expose thermostat wires and disconnect. Install 18 gauge (see W
IRING
 
D
IAGRAM
) or heavier wire through the grommet in the back, from the stove to the thermostat. Connect 
thermostat wires to red wires provided. 
3. To set the thermostat jumper to the desired mode, remove the two (2) screws holding the circuit board 
control panel in place.  Lower the board and pull out to change jumper. 
S
LIDER
/D
AMPER
 S
ETTING
:
THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE 
THE AIRFLOW THROUGH THE PELLET STOVE.
A Qualified Service Technician or Installer must set the Slider Damper.
The slider damper should be set only on a hot stove (operating for thirty (30) minutes or more) by placing 
a Magnahelic Pressure Gauge in the firebox (test port is located in the center of the stove just below 
the door opening). Set the slider damper so that the pressure reads  0.11” w.c. (.028 KPa) on HIGH 
A) HI / LOW: When the 
jumper  is  placed  on 
only one of the J9 pins, 
then  the  control  board 
is in a HI / LOW mode 
of thermostat operation 
(factory setting).    
Remove  jumper  wire  and  install  thermostat 
wires here
ON  /  OFF  OPERATION:    If 
the control board is placed with 
J9  jumped  then  the  control 
board  is  in  a  ON  /  OFF  mode 
of  operation.  In  the  ON  /OFF 
thermostat  mode,  when  the 
thermostat  calls  for  heat,  the 
unit will go through an ignition 
sequence  and  light  the  stove.  
Once lit the unit will operate at 
the selected setting displayed on 
the  control  board  Heat  Output 
Indicator.  Once the thermostat 
stops  calling  for  heat,  the  unit 
will  stop  feeding  pellets  and 
begin  its  shut  down  sequence 
until cold then turn off.
1.  Install  the  Low  Voltage 
Thermostat 
(maximum 
24V)  in  a  location  that  is 
not to close too the unit but 
will  effectively  monitor  the 
desired area to be heated.
Figure 47: Pin Placement on Circuit Board. 
B)  ON  /  OFF:  If  both 
pins  of  J9  are  jumped 
(covered),  the  control 
board is in an ON / OFF 
mode  of  thermostat 
operation.
Installation
T
HERMOSTAT
 I
NSTALLED
:
This control board can be placed into two (2) different modes: 
HI / LOW OPERATION: When the jumper J9 is not jumped then the control board is in a HI / LOW 
mode operation.  If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or 
idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will 
go to the setting that is displayed on the control board Heat Indicator. If the heating load is not great 
enough when the stove is on low, the high limit switch will turn the stove off and the switch will have 
to be manually reset. To reset the high limit switch, remove the right cabinet side. The switch is found 
behind the control panel. Avoid setting off the high limit switch.
32