Enviro Meridian User Manual

Page of 44
Operating Instructions
A
UTOMATIC
 S
AFETY
 F
EATURES
:
Your pellet Stove has the following safety features:
A)  The  stove  will shut  off  when  the  fire  goes  out  and the  exhaust  temperature  drops  below  120  °F 
(49°C).
B)  The stove has a high temperature safety switch.  If the temperature on the hopper reaches 200 °F 
(93 °C) the auger will automatically stop, and the stove will shut off when the exhaust temperature 
cools.  If this happens call your local dealer to reset the 200 °F (93 °C) high limit switch. FIND THE 
REASONS WHY THE UNIT OVERHEATED.
C)  This unit has a convection fan control over-ride. This function causes the convection fan to reach its 
full speed when the temperature at the back of the firebox reaches 160 °F (71 °C). This is a normal 
safety feature of your unit. 
D)  The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum 
switch will turn off the auger and the #2 light on the control board will flash.
C
ONTROL
 B
OARD
 F
UNCTIONS
:
1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim 
button until the number 1 and 5 lights appear on the Heat Level Indicator.  This will increase the feed 
rate to four (4) seconds ON time Auger pulse.  This is done only on LOW to allow the burning of poor 
quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On 
time to two (2) second. This setting is for high-grade fuel only.  Push the button until just the number 
1 light is on, this is for a three (3) second on time (standard setting).
2. CONVECTION BLOWER CONTROL: Used to turn the convection blower ON/OFF.  If the Blower is 
left off, and the sensor located on the air jacket reaches 160 °F (71 °C), the Convection blower will 
automatically come on HI speed to cool the unit. Leave the convection blower ON for peak efficiency
3. AUGER PULSE LIGHT: This light will flash in conjunction with the auger.
4. MANUAL AUGER FEED: If the unit runs out of fuel, this button can be used to “prime the auger 
 

 

 
1
3
4
5
6
2
8
7
system”. This button will turn off after 60 seconds and then must 
be released and pressed again.
5. SYSTEM  LIGHT:  Responsible  for  signaling  the  state  of  the 
control  board.  When  the  light  is  flashing  during  start-up,  the 
stove is in an automatic start mode. When the light is solid, the 
Heat Level Setting can be altered.
6. ON/OFF BUTTON: Used to turn the unit ON and OFF.
7.  HEAT OUTPUT INDICATOR: Shows the present heat output 
setting.
8. HEAT LEVEL ADJUSTMENT: When  pressed,  will  change  the 
heat setting of the unit from low to high.
Figure 1: Circuit Board Control Panel 
Decal.
Auger Trim
Auger Trim
Auger Trim
2 Seconds
"ON"
3 Seconds
"ON"
Factory Setting
4 Seconds
"ON"
1
1
1
4
5
Figure 2: Auger trim  and heat level indicator. 
6