Hearth & Home Technologies Bravo User Manual
Hearth & Home Technologies • Bravo, Aztec • InD • 703-900 Rev. N • 8/06
12
Figure 5.3
Figure 5.4
D. Vent Diagrams
WARNING
1. Top Vent - Horizontal Termination
One Elbow
Two Elbows
NOTE: When venting with one elbow, a
straight section of venting (3 ft. minimum)
MUST be attached directly to starting col-
lars on unit.
straight section of venting (3 ft. minimum)
MUST be attached directly to starting col-
lars on unit.
NOTE:
V
1
MUST be a
minimum of 3 feet.
V
1
Minimum
H
1
Maximum
3 ft.
0.9 m
2 ft.
0.6 m
4 ft.
1.2 m
4 ft.
1.2 m
5 ft.
1.5 m
6 ft.
1.8 m
12 ft.
3.7m
20 ft.
6.1 m
V
1
+ H
1
= 40 ft. (12.2 m) Maximum
H
1
= 20 ft. (6.1 m) Maximum
NOTE: The fi rst elbow used MUST always
be DVP90ST.
be DVP90ST.
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
NOTE: The first elbow used
MUST always be DVP90ST.
MUST always be DVP90ST.
V
1
Minimum
H
1
+ H
2
Maximum
3 ft.
0.9 m
2 ft.
0.6 m
4 ft.
1.2 m
4 ft.
1.2 m
5 ft.
1.5 m
6 ft.
1.8 m
12 ft.
3.7 m
20 ft.
6.1 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 20 ft. (6.1 m) Maximum