Hearth & Home Technologies Bravo User Manual

Page of 61
Hearth & Home Technologies  •  Bravo, Aztec  •  InD  •  703-900  Rev. N  •  8/06
6
3
Framing and Clearances
NOTE:
 Illustrations 
refl ect typical installations and are FOR 
DESIGN PURPOSES ONLY.
  I
llustrations/diagrams are not drawn to scale.
  Actual installation may vary due to individual design 
preference.
WARNING
Fire Risk
Provide adequate clearance:
•  Around air openings
• To 
combustibles
• For 
service 
access
Locate appliance away from traffi c areas.
A.   Selecting Appliance Location
When selecting a location for your appliance it is important to 
consider the required clearances to walls (see Figure 3.1).
Figure  3.1    Appliance Locations
NOTE:   For actual appliance dimensions refer to Sec-
tion 16.
A
B
C
D
E
Inches
45-1/8
34-3/8
63-7/8
25-1/4
No maximum
Millimeters
1146
873
1622
641
A
½
½
A
B
C
B
E
B
D
In addition to these framing dimensions, also reference the following sections:
•  Clearances and Mantel Projections (Section 3.C and 3.D)
•  Vent Clearances and Framing (Section 6).
NOTE:These dimensions 
are for fl ush wall fi nishing 
method. For a recessed 
arch fi nishing method refer 
to Option B in Finishing 
(Section 11).