28
A.   Recommendation for Wire
This appliance requires 110-120 VAC be wired to the 
junction box either for proper operation of the appliance 
(Intellifi re ignition). 
Electrical Information
10
NOTE: This appliance must be electrically wired and grounded 
in accordance with local codes or, in the absence of local 
codes, with National Electric Code ANSI/NFPA 70-latest 
edition 
or the Canadian Electric Code, CSA C221.1.
C.   Intellifi re Ignition System Wiring 
B.     Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
•  Incorrect wiring will damage millivolt valves.
•  Incorrect wiring will override IPI safety lock-
out and may cause explosion.
This appliance requires a 110 VAC supply to the appliance 
junction box for operation. A wiring diagram is shown in 
Figure 10.2.
This appliance is equipped with an Intellifi re control valve 
which operates on a 3 volt system. 
This appliance is supplied with a battery pack and a 3 volt 
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junc-
tion box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not in-
cluded). 
NOTE: Batteries cannot be placed in the battery pack 
while using the 3 volt AC transformer. The transformer 
must be unplugged if the battery pack is used or battery 
life will be reduced.
Wiring to the battery pack is left disconnected in order to 
conserve battery life. In the case of a loss of power, simply 
connect red and black wire leads to activate battery power 
(connect red to red, black to black). The fi replace can be 
used as necessary. Once power (110 VAC) is restored, 
disconnect red and black wire leads to extend battery 
life.
 CAUTION
Battery polarity must be correct or module damage will 
occur.
 Optional Accessories Requirements
Wiring for optional accessories should be done now to 
avoid reconstruction.
•  This appliance may be used with a wall switch, wall 
mounted thermostat and/or a remote control.
•  If using thermostat use one compatible with a millivolt 
gas valve system.
•  Follow parameters for locating thermostat (see individ-
ual thermostat instructions) to ensure proper operation 
of appliance.
•  Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.
•  Keep wire lengths short as possible by removing any 
excess wire length.
•  Low voltage and 110 VAC voltage cannot be shared 
within the same wall box.
D.   Wall Switch (Required)
A wall switch must be installed of this fi replace. This will 
allow the unit to operate if the power goes out (battery 
operation).
Position the wall switch in the desired position on the 
wall. An assembly of 18 ft of 20 AWG is provided with 
the appliance to connect the wall switch to the appliance. 
Instead of the supplied assembly, wire with a length of 
25 ft or less and a gauge of 20 AWG through 14 AWG is 
acceptable. The wire needs a jacket with a temperature 
rating of 140
o
F (60
o
C) or higher. At the appliance connect 
the wire to the ON/OFF switch pigtails.