Empire Comfort Systems VFHS-20R-4 User Manual

Page of 28
Page 18
16717-2-0605
If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the 
gas quality or pressure is low, contact your local gas supplier immediately.
  1.  When ignitor button is pressed, there is no spark at ODS/
pilot. 
a.  Ignitor electrode positioned wrong - Replace pilot.
b.  Ignitor electrode is broken - Replace pilot.
c.  Ignitor electrode not connected to ignitor cable - Recon-
nect ignitor cable.
d.  Ignitor cable pinched or wet. Keep ignitor cable dry - Free 
ignitor cable if pinched by any metal or tubing. 
e.  Broken ignitor cable - Replace ignitor cable.
f.  Bad piezo ignitor - Replace piezo ignitor.
  2.  Appliance produces unwanted odors.
a.  Appliance burning vapors from paint, hair spray, glues, 
etc. - Ventilate room. Stop using odor causing products 
while heater is running.
b.  Gas leak - Locate and correct all leaks.
  3.  Appliance shuts off during use. (Pilot and main burner 
are off.)
a.  Not enough fresh air is available for ODS/pilot to operate 
- Open window and/or door for ventilation.
b.  Low line pressure - Contact local gas company.
c.  ODS/pilot is partially clogged - Clean ODS/pilot.
d.  Defective thermocouple - Replace pilot.
  4.  Appliance shuts off during use. (Pilot stays on.)
a.  Low line pressure - Check line pressure to the valve.
b.  Defective thermopile - Check pilot flame, check wire con-
nections, output should be a minimum of 325 millivolts 
across. TH/TP  and TP  terminals  with  ON/OFF  switch 
off.
  5.  Gas odor even when control knob is in OFF position.
a.  Gas leak -
 Locate and correct all leaks.
b.  Control valve defective - Replace control valve.
  6.  When ignitor button is pressed, there is spark at ODS/pilot, 
but no ignition.
a.  Gas  supply  turned  off  or  manual  shutoff  valve  closed 
- Turn on gas supply or open manual shutoff valve.
b.  Control knob not in PILOT position - Turn control knob 
to PILOT position.
c.  Control  knob  not  pressed  in  while  in  PILOT  position 
- Press in control knob while in PILOT position.
d.  Air in gas lines when installed - Continue holding down 
control  knob.  Repeat  igniting  operation  until  air  is  re-
moved.
e.  ODS/pilot is clogged - Replace ODS/pilot assembly or 
get it serviced.
g.  Gas regulator setting is not correct - Replace gas regula-
tor. 
  7.  ODS/pilot lights but flame goes out when control knob is 
released.
a.  Control knob not fully pressed in - Press in control knob 
fully.
b.  Control knob not pressed in long enough - After ODS/pilot 
lights, keep control knob pressed in 30 seconds.
c.  Manual Shutoff valve not fully open - Fully open manual 
shutoff valve.
d.  Thermocouple connection loose at control valve - Hand 
tighten until snug, then tighten 1/4 turn more.
e.  Pilot  flame  not  touching  thermocouple,  which  allows 
thermocouple to cool, causing pilot flame to go out. This 
problem could be caused by either
 low gas pressure or 
dirty or partially clogged ODS/pilot - Contact local gas 
company. 
f.  Thermocouple damaged - Replace thermocouple.
h.  Control valve damaged - Replace control valve.
  8.  Burner does not light after ODS/pilot is lit.
a.  Burner orifice clogged - Clean burner or replace main 
burner orifice.
b.  Burner  orifice  diameter  is  too  small  -  Replace  burner 
orifice.
c.  Inlet gas pressure is too low - Contact qualified service 
person. 
  9.  If burning at main burner orifice occurs (a loud, roaring 
blow torch noise).
a.  You must turn off burner assembly and contact a qualified 
service person.
b.  Manifold pressure is too low - Contact local gas com-
pany.
c.  Burner orifice clogged - Clean burner or replace burner 
orifice.
 10.  Logs appear to smoke after initial operation.
a.  Vapors from paint or curing process of logs - Problem will 
stop after a few hours of operation. Run the heater with 
the damper open if you have one, or open a window for 
the first few hours. 
  Log heater is intended to be smokeless. Turn OFF heater 
and call qualified service person.
 11.  Heater produces a whistling noise when main burner is 
lit.
a.  Turning control knob to HIGH position when main burner 
is cold - Turn control knob to LOW position and let warm 
up for a minute.
b.  Air in gas line - Operate burner until air is removed from 
line. Have gas line checked by local gas company.
c.  Dirty or partially clogged burner orifice - Clean burner or 
replace burner orifice.
 12.  No gas to pilot.
a.  LP-regulator shut down due to inlet pressure too high - 
Verify LP tank regulator is installed and set at 11" to 13" 
w.c. Replace regulator on heater.
 
TROUBLESHOOTING
SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS
Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.