Empire Comfort Systems DVD42FP5 User Manual

Page of 52
23552-1-0607
Page 47
Attention:  Install blower assembly before connecting gas inlet 
supply line
Note:   Junction box on right side of fireplace must be pre-wired at 
time of fireplace installation for use with blower assembly. 
It is recommended that an ON/OFF wall switch be installed 
that will activate the power supply to the furnace by a 
qualified electrician.
1.  If installed, turn OFF gas supply to fireplace.
2.  If applicable, turn OFF electric supply to fireplace.
3.  Lower bottom louver on fireplace.
4.  Refer  to  page  49,  "Junction  Box  Wiring  Installation 
Instructions" to complete wiring of junction box.
Attention:  If  installed,  do  not  damage  gas  inlet  supply  line 
when blower assembly is inserted into fireplace. If 
necessary, remove gas inlet supply line.
5.  Insert  blower  assembly  into  interior,  bottom  of  fireplace. 
Position blower assembly behind gas valve, align notch on 
back of blower assembly with center screw on fireplace back 
and push blower assembly against fireplace back. The magnets 
on the back and bottom of blower assembly will sufficiently 
hold blower assembly in place.
6.  Position speed control box to the right of gas valve. Attach 
speed control box to bottom of fireplace. The magnets on 
bottom of speed control box will sufficiently hold speed control 
box in place.
7.  With base (flush face) of fan control switch facing upward, 
insert base of fan control switch under the mounting tabs on 
valve bracket. The base (flush face) of fan control switch must 
be in contact with bottom of firebox.
8.  Insert power cord plug into junction box.
9.  Close bottom louver on fireplace.
10. Installation of FBB4 optional variable speed blower assembly 
is completed.
Wiring
The appliance, when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI/NFPA 70, if an external 
electrical source is utilized. This appliance is equipped with a 
three-prong [grounding] plug for your protection against shock 
hazard and should be plugged directly into a properly grounded 
three-prong receptacle. Do not cut or remove the grounding 
prong from this plug. For an ungrounded receptacle, an adapter, 
which has two prongs and a wire for grounding, can be purchased, 
plugged into the ungrounded receptacle and its wire connected 
to the receptacle mounting screw. With this wire completing the 
ground, the appliance cord plug can be plugged into the adapter 
and be electrically grounded. 
Caution:  Label  all  wires  prior  to  disconnection  when 
servicing  controls.  Wiring  errors  can  cause  improper 
and dangerous operation. Verify proper operation after 
servicing.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to 
oil the blower motor.
Blower Wheels
The blower wheels will collect lint and could require periodic 
cleaning. If the air output decreases or the noise level increases, 
it indicates a dirty blower wheel. Remove fan and clean blower 
wheels.
Warning: Unplugging of blower accessory will not stop the 
heater from cycling. To turn off gas to the heater (millivolt 
model): push in gas control knob slightly and turn clockwise 
to "OFF." Do not force. To turn off gas on direct ignition 
model, turn gas line valve to "OFF."
VALVE BRACKET
FAN SWITCH
FAN KIT
SPEED CONTROL
JUNCTION BOX
SWITCH HOLDER
(TOP OF VALVE BRACKET)
SEE NOTE
Note:  Refer  to  wiring  instructions  on  page  48  for  proper 
operation
.
FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION