Enviro Omega User Manual

Page of 16
7
Operating Instructions
C
ONTROL
 B
OARD
 F
UNCTIONS
:
1.  ON/OFF BUTTON: Used to turn the unit ON and OFF manually.
2.  FUEL TYPE BUTTON: Used to switch between fuel type modes; Pellet (for all qualities of wood 
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
1
2
3
4
5
6
7
pellets)  and  Multifuel  (for  all  fuels  including  wood 
pellets). When set on Multifuel it will run at a reduced 
High Feed Rate with wood pellets. NOTE: Fuel Type 
can only be chnaged when the unit is cold.
3.  THERMOSTAT  SWITCH:  Sets  the  unit’s  control 
mode;  AUTO/OFF  or  HIGH/LOW  (when  using  a 
Thermostat or Timer) or MANUAL.
4.  FUEL  TYPE  LIGHTS:  Shows  the  present  Fuel  Type 
selected;  Pellet  is  green  and  Multifuel  is  yellow.  The 
light flashs during start-up and stops flashing when the 
49°C (120°F) switch closes.
5.  HEAT  OUTPUT  INDICATOR:  Shows  the  present 
Heat Level output setting and the Feed Trim while it is 
being adjusted.
6.  HEAT  LEVEL  ADJUSTMENT  BUTTONS:  When 
pressed, will change the heat setting of the unit from 
low  to  high.  Arrow  up  button  to  increase  heat  and 
arrow down to decrease heat.
7.  FEED TRIM BUTTON: Used in conjunction with the 
Heat Level adjustment buttons to adjust the Feed Trim. 
It can be increased by two (2) feed settings or it can be 
decreased by two (2) feed settings. The Feed Trim can 
only be adjusted one setting at a time. This button can 
also be used to “prime the auger system”. 
Figure 2: Circuit Board Control Panel Decal
A
UTOMATIC
 S
AFETY
 F
EATURES
 
OF
 Y
OUR
 P
ELLET
 S
TOVE
:
A.  EXHAUST TEMPERATURE SWITCH: The stove will shut off when the fire goes out and the exhaust 
temperature drops below 49°C (120°F).
B.  HIGH LIMIT SAFETY SWITCH: If the temperature on the hopper reaches 93°C (200°F), the auger will 
automatically stop, the stove will shut down, and it will display a #4 flash code.  If this happens, call 
your local dealer to reset the 93°C (200°F) high limit switch. ALSO FIND THE REASONS WHY THE 
UNIT OVERHEATED.
C.  VACUUM SWITCH: If the combustion fan fails or the exhaust vent becomes blocked this switch will 
stop the auger feed motor and the fire will go out.
O
PERATING
 Y
OUR
 P
ELLET
 S
TOVE
:
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH BOX OPEN. Keep hopper lid closed 
except during re-fuelling.
CAUTION: 
When  operating  during  adverse  weather,  such  as  high  winds  or  freezing  rain,  if  the  unit 
exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust 
outlet.