Mitsubishi Electronics PKH24FL User Manual

Page of 53
4
3
SPECIFICATIONS
FK
1
:48 -41
Capacity
Moisture removal
Power
Consumption
EER
SEER
HSPF
COP
INDOOR UNIT MODELS
External finish
Power supply
Max.fuse size (time delay)
Min.ampacity
Fan motor
Booster heater
Airflow Hi-Lo
Sound level Hi-Lo
Unit drain pipe O.D.
Dimensions
Weight
OUTDOOR UNIT MODELS
External finish
Power supply
Max.fuse size (time delay)
Min.ampacity
Fan motor
Compressor
Crankcase heater
Refrigerant control
Defrost method
Sound level
Dimensions
Weight
REMOTE CONTROLLER
Control voltage (by built-in transformer)
REFRIGERANT
REFRIGERANT PIPING
Pipe size
Connection
method
Between the indoor
& outdoor units
Cooling   *1
Heating   *1
Heating   *2
Cooling   *1
Heating   *1
Heating   *2 
               *1
               *1
               *2
Dry
Wet
W
D
H
Model (type)
W
D
H
Name
Charge
Oil <Model>        
Liquid
Gas
Indoors
Outdoors
Height difference
Piping length
Btu/h
Btu/h
Btu/h
Pints/h
kW
kW
kW
V,phase,Hz
A
A
F.L.A.
A(kW)
CFM
CFM
dB
in.
in.
in.
in.
lb
V,phase,Hz
A
A
F.L.A.
R.L.A.
L.R.A.
A(W)
dB
in.
in.
in.
lb
L
in.
in.
ft
ft
PKH18FL
Model
18,000
18,600[24,100/25,100]
10,700[16,200/17,200]
5.3
1.79
1.56[3.16/3.46]
1.34[2.94/3.24]
10.1
11.1
7.2
3.5
2.3
PKH18FL
57
PUH18EK
20
16
0.75
RH247NAB
12
37
0.11/0.12[23/28]
53
33-1/2
131
5 lbs 8 oz
0.52 <MS-56>
130
130
PKH24FL
24,000
25,000[30,500/31,500]
14,700[20,200/21,200]
7.0
2.36
2.37[3.97/4.27]
1.92[3.52/3.82]
10.2
10.2
6.8
3.1
2.2
PKH24FL
                                                      Munsell 3.4Y 7.7/0.8
                                                    208/230,1,60
57
PUH24EK
1
                                                    Munsell 5Y 7/1
                                                  208/230,1,60
20
16
0.65+0.65
NH33NBD
11.5
54
0.16/0.17[33/39]
                                                  Capillary tube
                                                   Reverse cycle
55
49-9/16
202
                                                With indoor unit
                                                  Indoor unit-remote controller:DC12V. Indoor unit-outdoor unit:DC12V
                    R22
9 lbs 15 oz
1.2 <MS32N-1>
Not supplied(optional parts)
                                                 Flared
                                                 Flared
9-1/4
13-3/8
PKH30FL
30,000
33,000[39,100/40,500]
19,000[25,100/26,500]
9.1
3.12
3.02[4.82/5.22]
2.48[4.28/4.68]
9.6
10.6
7.1
3.2
2.2
PKH30FL
 
FK
1
:49-44
66
PUH30EK
1
30
20
0.75+0.75
NH41NAD
14.0
73
0.16/0.17[33/39]
55
38-3/16
13-9/16
49-9/16
245
10 lbs 2 oz
                                                  1.3 <MS32N-1>
1/2
3/4
PKH36FL
34,200
38,000[44,100/45,500]
19,600[25,700/27,100]
10.5
3.44
3.54[5.34/5.74]
2.65[4.45/4.85]
9.9
10.5
6.9
3.1
2.2
PKH36FL
FK
1
:50-46
66
PUH36EK
1
30
22
0.75+0.75
NH47NAD
17.5
87
0.16/0.17[33/39]
55
38-3/16
13-9/16
49-9/16
246
10 lbs 9 oz
1/2
3/4
164
164
Item
34-1/4
11-5/8
3/8
5/8
164
164
55-1/8
66-5/32
NOTES : *1.Rating conditions (cooling)-indoor : 80˚FDB,67˚FWB outdoor : 95˚FDB,75˚FWB.
                                                 (heating)-indoor : 70˚FDB,60˚FWB outdoor : 47˚FDB,43˚FWB.
                *2.Rating conditions (heating)-indoor : 70˚FDB,60˚FWB outdoor : 17˚FDB,15˚FWB.
                *3.Heating capacity and power consumption in [   ] includes heater operation at 208/230V.
Operating range
Indoor intake air temperature
95˚FDB,71˚FWB
67˚FDB,57˚FWB
80˚FDB,67˚FWB
70˚FDB,60˚FWB
Outdoor intake air temperature
115˚FDB
0˚FDB *
75˚FDB,65˚FWB
17˚FDB,15˚FWB
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
1-1/16 (or 7/8)
15
12
13
0.5
0.6
7.6/8.4[1.6/1.9]
710-530
640-480
8.7/9.6[1.8/2.2]
990-780
890-700
*
In case of the wind baffle is installed.
(In case of the wind baffle is not installed, the minimum temperature will be 23˚FDB.)
 
MODELS : PKH18FL, PKH24FL, PKH30FL, PKH36FL
OC276-A-1.qxp  03.11.25 9:04 AM  Page 4