Mitsumi electronic MSZ-GA80 VA User Manual

Page of 8
1
2
H
D
C
7
B
G
3
6
8
8
E
F
K
4
A
7 mm or more
500 mm or more
100 mm or more
100 mm or more
500 mm or more
350 mm or more
Note: Do not
obstruct the
air outlet.
72 mm or more
100 mm or more for left and left
back piping (using spacer)
120 mm
or more
200 mm
or more
5
Air outlet
4-10 mm 
× 21 mm slot
Be careful the
drain hose is not
raised.
Separate the 2 connecting pipes and
apply insulation individually.
8 mm thickness thermal insulation
plastic
Decide the installation position using mark on the installation
plate indicating the indoor unit size as reference.
When the piping is to be attached to a
wall containing metals (tin plated) or
metal netting, use a chemically treated
wooden piece 20 mm or thicker
between the wall and the piping or
wrap 7 to 8 turns of insulation vinyl
tape around the piping.
Lock the catch.
Front
Piping can be directed towards rear,
right, downward, left or left-rear
directions.
Rear side
Right
Rear
Downward
Left-rear
Left
Units should be installed by licensed contractor according
to local code requirement.
PIPING PREPARATION
1 Specifications
Use the refrigerant pipes that meet the following specifications.
840 mm
330 mm
360 mm
500 mm
100 mm
15 mm
17 mm
10.5 mm
Heat resisting
foam plastic
0.045 specific
gravity
Use a copper pipe or a copper-alloy seamless pipe with a thickness of 0.8 mm
(for ø6.35, 9.52) or 1.0 mm (for ø12.7, ø15.88). Never use any pipe with a thickness
less than 0.8 mm (for ø6.35, 9.52) or 1.0 mm (for ø12.7, ø15.88), as the pressure
resistance is insufficient.
2 Ensure that the 2 refrigerant pipes are insulated to prevent condensation.
3 Refrigerant pipe bending radius must be 100 mm or more.
 CAUTION
Be sure to use the insulation of specified thickness. Excessive thickness may cause
incorrect installation of the indoor unit and lack of thickness may cause dew drippage.
8
8
8
8
Pipe
Outside diameter
Insulation thickness
Insulation material
mm
mm
For liquid
For gas
GA50/GA60
GA71/GA80
GA50
GA60/GA71/GA80
6.35
9.52
12.7
15.88
3. INSTALLATION DIAGRAM & ACCESSORIES
FLARED CONNECTIONS
This unit has flared connections on both indoor and outdoor sides.
Remove the outdoor units valve cover, then connect the pipe.
Refrigerant pipes are used to connect the indoor and outdoor units.
Be careful not to crush or bend the pipe in pipe bending.
Limits
MSZ-GA50/60/71/80
Pipe length
30 m max.
Height difference
15 m max.
No. of bends
10 max.
Refrigerant adjustment ... If pipe length exceeds 7 m, additional refrigerant
(R-410A) charge is required.
(The outdoor unit is charged with refrigerant for pipe length up to 7 m.)
Pipe length
Up to 7 m
No additional charge is required.
Exceeding 7 m
Additional charge is required.
(Refer to the table below.)
MSZ-GA50
20 g/m 
× (refrigerant piping length (m) -7)
MSZ-GA60
20 g/m 
× (refrigerant piping length (m) -7)
MSZ-GA71
55 g/m 
× (refrigerant piping length (m) -7)
MSZ-GA80
55 g/m 
× (refrigerant piping length (m) -7)
Indoor/outdoor unit connecting wire
1
(4-core 1.0 mm
2
-2.0 mm
2
)
Extension pipe
1
Wall hole sleeve
1
Wall hole cover
1
Pipe fixing band (The quantity depends
on the pipe length.)
2 to 5
Fixing screw for 
 4 
× 20 mm (The
2 to 5
quantity depends on the pipe length.)
Piping tape
1
Putty
1
Drain hose (or soft PVC. hose, 15 mm
1
inner dia. or hard PVC pipe VP16)
Refrigeration oil
1
Power supply cord (See the table in 5
INDOOR/OUTDOOR WIRE CONNECTION
1
AND OUTDOOR POWER SUPPLY CORD
CONNECTION for the cord size.)
Note:
When operating the air conditioner in low outside temperature,
be sure to follow the instructions described below.
Never install the outdoor unit in a place where its air inlet/outlet
side may be exposed directly to wind.
To prevent exposure to wind, install the outdoor unit with its
air inlet side facing the wall.
To prevent exposure to wind, it is recommended to install a
baffle board on the air outlet side of the outdoor unit.
PART TO BE PROVIDED AT YOUR SITE
Optional extension pipe
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
Installation plate
1
Installation plate fixing screw 4 
× 25 mm
7
Remote controller holder
1
Fixing screw for 
 3.5 
× 16 mm (Black)
2
Battery (AAA) for remote controller
2
Wireless remote controller
1
Felt tape (Used for left or left-rear piping)
1
Anti-allergy enzyme filter
2
Refrigerant to
be added
1800 mm or
more from
the floor