Mitsubishi P336 User Manual

Page of 334
I  Read Before Servicing ] 
- 3 -
HWE09120
GB
I Read Before Servicing
[1] Read Before Servicing
1.  Check the type of refrigerant used in the system to be serviced.
Refrigerant Type
Multi air conditioner for building application CITY MULTI TJMU-A, YJMU-A series R410A
2.  Check the symptoms exhibited by the unit to be serviced.
Refer to this service handbook for symptoms relating to the refrigerant cycle.
3.  Thoroughly read the safety precautions at the beginning of this manual.
4.  Preparing necessary tools: Prepare a set of tools to be used exclusively with each type of refrigerant.
Refer to "Necessary Tools and Materials" for information on the use of tools.(page 4)
5.  Verification of the connecting pipes: Verify the type of refrigerant used for the unit to be moved or replaced.
ŒUse refrigerant pipes made of phosphorus deoxidized copper. Keep the inner and outer surfaces of the pipes clean and free 
of such contaminants as sulfur, oxides, dust, dirt, shaving particles, oil, and water.
ŒThese types of contaminants inside the refrigerant pipes may cause the refrigerant oil to deteriorate.
6.  If there is a leak of gaseous refrigerant and the remaining refrigerant is exposed to an open flame, a poisonous gas 
hydrofluoric acid may form. Keep workplace well ventilated. 
CAUTION
ŒInstall new pipes immediately after removing old ones to keep moisture out of the refrigerant circuit.
ŒThe use of refrigerant that contains chloride, such as R22, will cause the refrigerating machine oil to deteriorate.