Mitsubishi PJZ012A087B User Manual

Page of 22
12
7 
Press 
 SET button (Fixing of the upper 
limit position)
The upper limit position is fixed and the setting position is 
displayed for two seconds. Then proceed to lower limit position 
selection display.
[EXAMPLE]
” (lit for two seconds)
È
” (shows current setting)
Press 
 or  button (Selection of lower limit 
position)
Select the lower limit position of louver.
“position 1” is the most horizontal, and “position 6” is the most 
downwards.
“position --” is to return to the factory setting. If you need to change 
the setting to the factory setting, use “position --”.
” (the most horizontal)
⇔ “
⇔ “
⇔ “
⇔ “
⇔ “
” (the most downwards)
⇔ “
” (return to the position of shipmen)
Press 
 SET button (Fixing of the lower limit 
position)
Upper limit position and lower limit position are fixed, and the set 
positions are displayed for two seconds, then setting is completed.
•  After the setting is completed, the louver which was set 
moves from the original position to the lower limit position, 
and goes back to the original position again. (This operation 
is not performed if the indoor unit and/or indoor unit fan is in 
operation.)
[Example]
” (lit for two seconds)
È
È
10
 Press 
 button.
Louver adjusting mode ends and returns to the original display.
 
HOW TO SET THE AIRFLOW DIRECTION 
< WIRED REMOTE CONTROL >
NOTICE
(downwards)
(horizontal)
the position of the louver
[EXAMPLE]  For Upper position 2, Lower position 6
Upper
position
Lower
position
Movable
range
•  When plural remote controllers are connected, louver position setting cannot be set by slave remote control.
•  If you press 
 RESET button during settings, the display will return to previous display. If you press 
 
button during settings, the mode will be ended and return to original display, and the settings that have not been 
completed will become invalid.
Note : If the upper limit position number and the lower limit 
position number are set to the same position, the 
louver is fixed at that position. And auto swing does 
not function.
Clean the filter frequently
 
See page 16
If the filter is clogged…
•  The cooling/heating capacity will get reduced. Moreover it leads 
to waste of electricity and larger operation noise.
•  It may cause failure.
•  Dew may form and drop during cooling.
Do not block the inlet and outlet grilles of the 
indoor and outdoor units.
Excessive load to the unit may cause failure.
Keep moderate room temperature
Too much cooling or heating is not good for your health. It will also 
waste the electricity.
Block direct sunlight and prevent draft
Block direct sunlight with blinds and curtains during cooling. Close 
the windows and doors except when ventilation is necessary.
Adjust the airflow properly
Do not expose yourself directly to the airflow for too long time. For 
small animals and plants, it is harmful as well.
If you feel cold underneath your feet during heating
If the ceiling is so high that the warm airflow does not circulate 
underneath your feet, it is recommended to use a circulator. 
Consult your dealer for more detail.
Stop the operation and turn the power supply 
off if there are any possibility of lightning 
strikes during a thunderstorm.
Lightning strikes may lead to the failure of air-conditioning system.
 
FOR COMFORTABLE USE
The filter should be cleaned when 
the “Filter cleaning” message 
is displayed, and at the end of 
cooling and heating seasons.
 
HOW TO OPERATE VENTILATION 
(WHEN A VENTILATOR IS INSTALLED)  < WIRED REMOTE CONTROL >
Press “
 
VENTI” button.
” is displayed, and the ventilation operation begins.
Stop
 Press “
 VENTI” button again.
When the ventilator is set to “NO VENTI LINK”, the ventilator can be turned on and off independently regardless 
of the operation of the air conditioner.
When the ventilator is set to “VENTI LINK”, the ventilator operation will be interlocked with the air conditioner 
operation.
NOTICE
  If no ventilator is connected, no operation can be performed by 
pressing the ventilation button. (“
” is displayed).
VENTILATION OPERATION NOT LINKED WITH UNIT’S 
OPERATION
Press 
 button.
If a ventilator is connected, ventilation will operate automatically.
” is displayed.
Stop
 Press 
 button again.
NOTICE
•  No operation can be performed by pressing the ventilation button. 
(“
” is displayed).
VENTILATION OPERATION LINKED WITH UNIT’S OPERATION
 
AIROUTLET SELECTION 
(IN CASE OF FDFW)
It is possible to switch between the combination of upper and lower air outlets and upper air outlet.
Not operable while the air conditioner is ON.
When the upper airflow is selected, UPPER AIR FLOW LED on the unit display will light green only under run.
<WIRED REMOTE CONTROL>
1.  Stop the air conditioner.
2.  Set the upper land lower limit position of the louver No.1 from the wired remote control.
 
For the method of changing the setting, refer to HOW TO SET THE AIRFLOW DIRECTION on page 11.
A  In case of selecting to upper airflow.
Set the upper and lower limit position to UPPER 2 and LOWER 2. (No.1 UPPER 2 / LOWER 2)
B  In case of selecting to upper and lower airflow.
Set the upper and lower limit position to UPPER 5 and LOWER 5. (No.1 UPPER 5 / LOWER 5)
<WIRELESS REMOTE CONTROL>
AIR SELECTION button can switch the air outlets.
1.  Stop the air conditioner.
2.  Select the airflow from AIR SELECTION button on the unit display.
A  In case of selecting to upper airflow.
Press the AIR FLOW SELECTION button once.
UPPER AIR FLOW LED will light for ten seconds.
B  In case of selecting to upper and lower airflow.
When UPPER AIR FLOW LED is lit by pressing AIR FLOW SELECTION button, press AIR FLOW 
SELECTION button once again.
UPPER AIR FLOW LED will turn off.