Sharp AE-X9FR User Manual

Page of 14
AYXP7FR
1 – 2
2. AY-XP9FR – AE-X9FR
MODEL
INDOOR UNIT
OUTDOOR UNIT
ITEMS
AY-XP9FR
AE-X9FR
Cooling capacity(Min. > Max.)
kW
2.64 (0.9 - 3.0)
Heating capacity(Min. > Max.)
kW
3.1 (0.9 - 4.8)
Moisture removal(at cooling)
Liters/h
Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage
V
230
Rated current 
(Min - Max.)
Cool
A
3.7 (1.0 - 4.8)
Heat
A
3.5 (0.9 - 6.1)
Rated input 
(Min - Max.)
Cool
W
780 (200 - 960)
Heat
W
730 (160 - 1400)
Power factor 
Cool
%
92
Heat
%
91
Compressor
Type
Hermetically sealed rotary type
Model
DA89X1F-23F
Oil charge
370cc (VG74)
Refrigerant system
Evaporator
Louver Fin and Grooved tube type
Condenser
Corrugate Fin and Grooved tube type
Control
Expansion valve
Refrigerant (R410A)
830g
De-lce system
 Micro computer controled reversed systems
Noise level
(at cooling)
High
dB(A)
39
45
Low
dB(A)
Soft
dB(A)
28
Fan system
Drive
Direct drive
Air flow quantity
(at cooling)
High
m3/min.
8.6
23.3
Low
m3/min.
7.3
Soft
m3/min.
5.5
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
Drain piping mm
O.D 
φ18
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm
790
730
Height
mm
278
540
Depth
mm
198
250
Net weight
kg
10
33