Sanyo SAP-KRV123EH User Manual

Page of 77
7
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit
SAP– KRV93EH
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Control PCB
Part No.
CB-KRV93EH (POW-KRV93GJH)
Controls
Microprocessor
Control circuit fuse
250V   3.15A
Flap Motor and Louver Motor
Type
Stepping motor
Model
MP24Z3-12V
Rating
DC 12V
Coil resistance (Ambient temp. 25°C)
Ω
Each pair of terminals: 400 ± 7%
Heat Exchanger Coil
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
mm
1.3
Face area
m
2
0.188
Fan & Fan Motor
Type     Fan / Fan motor
Cross-flow / AC motor
Q’ty … Dia. and length
mm
1 … D92 / L634
Fan motor model … Q’ty
IBH-884-066 … 1
No. of poles … Rough measure rpm (Cool / Heat)
4 … 1,200 / 1,250
Nominal output
W
30
Coil resistance (Ambient temp. 20°C)
Ω
BRN – WHT: 234
PNK (RED) – WHT: 209
— :
Safety devices
Type
Thermal fuse
Operating temp.
Open
°C
130
Close
Run capacitor
µF
1.2
VAC
440
Remote Control Unit
RCS-3HVPSS4E