Sanyo KH3072R / C3072R User Manual

Page of 180
II-3
SM831148
1
2
3
4
5
6
2. Processes and functions
Fig. 2
THERMO.  ON
THERMO.  ON
+2
°F
F
F
O
F
F
O
2
1.  Refer  to  2-4  Outdoor Fan Speed Control
OFF
SET SPEED
N
O
N
O
N
O
ON (REVERSING CYCLE)
ON
TEMP.
OPERATION
REMOTE CONTROL 
SENSOR
(Only for wireless 
remote controller)
BODY SENSOR
OFF
OFF
SET SPEED
SET SPEED
3 SECONDS
ON
OFF
ON
MORE THAN
3 MINUTES
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
3 MINUTES
MORE THAN
5 MINUTES
5 MINUTES
THERMO.  ON
THERMO.  ON
THERMO.  ON
THERMO.  ON
2.  Refer  to  2-2  Cold Draft Prevention (Heating)
BUTTON
COIL (4-WAY)
SOLENOID
E2
TEMP.
COIL
EXCH.
INDOOR HEAT
STANDBY
2
INDOOR FAN
1
OUTDOOR FAN
(H OR M)
COMPRESSOR
SET. +2
°F
SET. –2
°F
–2
°F
SET TEMP.+7
°F SHIFT
THERMO.  OFF
THERMO.  OFF
OFF
(88
°F)
81
°F
77
°F
1134_THS_I
THERMO.  OFF
THERMO.  OFF
LL
LL
LL
L
L
SETTING TEMP.
SET TEMP. 
Chart Summary and Explanations
Once the compressor starts, it keeps running for 5 minutes.
Once the compressor stops, it will not start running again for 3 minutes.
If you change the operation mode (HEATCOOL or FAN) during the heating cycle, the
control circuit stops the compressor for 3 minutes.
For 5 minutes after the compressor is first turned on, and for 3 minutes after it is turned off,
the compressor is not controlled by the room sensor.
When set on remote control sensor
Thermo ON: When room temperature is –2˚F below the set temperature T˚.
Compressor
  ON
Thermo OFF: When the room temperature is 2˚F above the set temperature T˚, (T˚+2 ˚F)
Compressor
   OFF
When set on body sensor
NOTE: In case of Body sensor, operating temperature is shifted to setting temperature +7
˚F.
(B) Heating