2. NOTICES FOR USER
5
Principle:
Air conditioner absorbs heat in the room and transmit to 
outdoor and discharged, so that indoor ambient 
temperature decreased. It's cooling capacity will decrease 
by the increase of outdoor ambient temperature.
Anti-freezing Function:
If the units is running in COOL mode and in low 
temperature,  there will be frost formed on the heat 
exchanger, when indoor heat exchanger temperature 
decreased below 0  C, the indoor unit micro-computer will 
stop compressor running and protect the unit.
2.1  Working Principle & 
      Special  Functions 
      for Cooling 
o
Operation and Maintenance
2.2 Working Temperature Range
2.3 The Conditions of Unit Can't Operate Normally. 
In the following temp. range, the protection device may act, this may cause unit stop running. 
The operating temperature range (outdoor temperature) for cooling unit is 21 
°C
 ~ 52 
°C
.
Under the relative humidity is above 80% ( doors and windows are opened) when cooling or 
dehumidifying for a long time, there may have dew drip off near the air vent. 
COOLING
  Temperature          Indoor air temperature
Outdoor air temperature
Max.
Min.
32
°C DB / 23 °C WB
21
°C DB / 15 °C WB
52
°C DB / --- 
21
°C DB / ---
“COOL” running
“DRY” running
Outdoor temperature 
above
Outdoor temperature  
below
Indoor temperature 
above
52
°C   
 
32
°C
18
°C                                  
32
°C
21
°C                             
52
°C