RGE13      Package Gas / Electric
seer
13
Performance
 
Model
Cooling
Heating 
BTUH
SEER
EER 
S/T
CFM
Input 
BTUH
Output 
BTUH
Efficiency 
AFUE
Temp 
Rise 
Range °F
RGE13A24050(L)P
22,800
13.0
11.0
0.73
800
50,000
40,000
80%
30 - 60
RGE13A24075(L)P
75,000
60,000
35 - 65
RGE13A30050(L)P
28,000
13.0
11.0
0.74
1000
50,000
40,000
80%
30 - 60
RGE13A30075(L)P
75,000
60,000
35 - 65
RGE13A36075(L)P
34,000
13.0
11.0
0.71
1200
75,000
60,000
80%
35 - 65
RGE13A36100P
100,000
80,000
45 - 75
RGE13A42075(L)P
40,000
13.0
11.0
0.75
1400
75,000
60,000
80%
30 - 60
RGE13A42100(L)P
100,000
80,000
40 - 70
RGE13A48100(L)P
46,000
13.0
11.0
0.75
1600
100,000
80,000
80%
40 - 70
RGE13A48125P
125,000
100,000
45 - 75
RGE13A60100(L)P
56,000
13.0
11.0
0.72
1800
100,000
80,000
80%
40 - 70
RGE13A60125P
125,000
100,000
45 - 75
Blower Performance
Model
Blower 
Tap* 
(1 - 5)
CFM @ ext. Static Pressure in in. wc without filter, dry coil
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
RGE13A24***(L)P
1
500
480
420
340
290
240
---
---
2
830
790
760
710
640
600
560
520
3
950
920
890
850
810
740
700
660
RGE13A30***(L)P
1
630
550
470
420
380
320
---
---
2
1020
990
960
920
890
850
790
740
3
1100
1060
1030
1010
990
950
900
840
RGE13A36***(L)P
1
760
680
600
550
490
---
---
---
2
1250
1210
1180
1130
1090
1060
1010
960
3
1370
1330
1280
1250
1210
1170
1120
1040
RGE13A42***(L)P
1
860
780
710
660
600
560
---
---
2
1460
1400
1340
1280
1230
1180
1140
1100
3
1600
1560
1500
1450
1400
1320
1230
1150
RGE13A48***(L)P
1
970
890
820
780
740
680
---
---
2
1680
1640
1590
1540
1450
1330
1260
1180
3
1890
1820
1730
1620
1540
1430
1300
1210
RGE13A60***(L)P
1
1200
1130
1070
990
930
860
-
-
2
1870
1840
1800
1760
1700
1650
1600
1550
3
2010
1970
1930
1890
1850
1810
1760
1700
Add .10 Duct Static for Downflow CFM
     * Tap 1 - Fan Only
        Tap 2 - Low Static Cooling
        Tap 3 - High Static Cooling
Taps 4 & 5 designed for Heating mid point temperature rise @:
    Tap 4 - Nominal .2 ESP
    Tap 5 - Nominal .5 ESP
- Page 3 -