Desa 160-IF User Manual

Page of 48
www.desatech.com
114909-01A
4
4.  Flip switch (3 on Electric Control Panel
page 7) to the position with the symbol: 
 - the fan should start and after several 
seconds the heater should ignite.
The first time the heater is used or after the fuel 
circuit has been completely drained, the flow of 
fuel oil to the nozzle may be insufficient and may 
activate the flame control, which will turn off the 
heater; if this happens, wait for about a minute and 
then press the reset button (1 on Electric Control 
Panel, page 7) to start the heater again.
TO STOP HEATER
1.  Move switch (3 on Electric Control Panel, page 
7) to the “0” position or adjust the control mech-
anism, for example turning the thermostat to a 
lower position. The flame will go out and the fan 
will continue to function until the combustion 
chamber has cooled down completely.
2.  Wait until fan stops before unplugging heater. 
Unplug heater when not in use.
THERMOSTAT 
OPERATION
The heater can only work automatically when a 
thermostat is connected to it by attaching the cable 
to terminals 2 and 3 of plug (4 on Electric Control 
Panel, page 7).
MOVING AND 
TRANSPORTING HEATER
  WARNING:  Before  moving 
the  heater  you  must  turn  the 
heater off (see To Stop Heater), 
disconnect  the  plug  from  the 
power  supply  and  wait  for  the 
heater to cool.
Before lifting or moving the heater, make sure that 
the fuel tank cap is firmly in place.
The heater may be supplied in a portable version, 
with wheels or a suspended version, mounted on a 
support structure and fixed in place with wires or 
chains. In the former case, to move the heater, sim-
ply grasp the support handle and move the heater. 
In the latter case, the heater must be lifted with a 
fork-lift truck or a similar piece of equipment.
FUELS
  WARNING:  Use  only  kero-
sene, #1/#2 diesel/fuel oil, JET A 
or JP-8 fuels to avoid risk of fire or 
explosion. Never use gasoline, oil 
drained from crankcases, naph-
tha,  paint  thinners,  alcohol  or 
other highly flammable fuels.
Use only kerosene, #1/#2 diesel/fuel oil, JET A 
or JP-8 fuels. Heavier fuels such as No. 2 fuel 
oil or No. 2 diesel fuel may also be used but will 
result in:
•  noticeable odor
•  additional fuel filter maintenance
•  the need for nontoxic, anti-icer additives in very 
cold weather
Do  not  use  fuels  heavier  than  No.  2  grade  or 
heavy oils such as oil drained from crankcases. 
These heavy oils will not ignite properly and will 
contaminate the heater.
IMPORTANT:
 Use a KEROSENE ONLY (blue) 
or DIESEL ONLY (yellow) storage container. Be 
sure storage container is clean. Foreign matter 
such as rust, dirt or water will cause the ignition 
control assembly to shut down heater. Foreign 
matter may also require heaterʼs fuel system to 
be frequently cleaned. 
TO START HEATER
IMPORTANT: Review and under-
stand the warnings in the Safety 
Information section, page 2. They 
are  needed  to  safely  operate 
this  heater.  Follow  all  local  or-
dinances and codes when using 
this heater.
1.  Fill tank with fuel (see Fuels).
2.  Plug heater power cord into approved, grounded, 
120V/60Hz, 3 prong outlet or extension cord.
 
Extension Cord Size Requirements
 
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG 
(0.75 mm
2
) rated cord
 
11 to 100 feet (3.3 to 30.5 meters) long, use 
16  AWG (1.0 mm
2
) rated cord
 
101 to 200 feet (30.8 to 61 meters) long, use 
14 AWG (1.5 mm
2
) rated cord
3.  If a thermostat is connected, adjust it to the 