Sunpentown Intl WA-1230E User Manual

Page of 9
 
 
 
 
Model Number 
  
WA-1010E 
WA-1010M 
WA-1010H 
  
Cooling Capacity 
10,000BTU/hr 10,000BTU/hr 
Heating Capacity (1)(2) 
N/A 
10,000BTU/hr 
Power Consumption 
660W / 6.3A 
660W / 6.3A 
Humidity Removal Capacity  50 pts./day 
50 pts./day 
Recommended Room Size* 
300 sq. ft. 
300 sq. ft. 
Power Supply 120V / 60H  / 1 Phase 120V / 60H  / 1 Phase 
Compressor Rotary 
Rotary 
Refrigerant R-22 
R-22 
Fan Speed 
Timer 
WA-1010E: 1-12hours 
1-12 hours 
  
WA-1010M: 1-8hours 
  
Thermostat 
64°F - 90°F 
64° F - 90°F 
Net Weight 
Dimensions 
17"W x 17"D x 30"H 
17"W x 17"D x 30"H 
Working Temperature 
  
Cooling: 64°F to 110°F 
  
Cooling: 64°F to 110°F 
Heating: 41°F to 81°F 
    REMARKS: 
    1. The data may vary, please refer to the rating label on the back on the back of the unit. 
  
    2. The above conditions are measured at: 
       Cooling - Indoor: RT 81°F, RH 60% 
       Heating - Indoor: RT 68°F, RH 60% 
  
    * Uninsulated rooms such as sunrooms, garages, or attics should be less than 300 sq. ft. 
 
Specifications
Drainage
During the process of cooling or heating, some water will be extracted from the air into the unit.  Most of
this water is used to cool the unit and make it run more efficiently. This is a feature not found in most
Portable Air Conditioners.  If the unit is operated in VERY HUMID air, water will collect in the container
inside the unit. If the water container is full, the compressor and fan will stop. The POWER indicator will
blink to inform you to empty the  
internal container. To make the cooling function work again, please  
empty the water by one of the following methods: 
2
12
By the Draining into a Container
Use a Shallow Container or Dish 
1. Turn off the unit. 
2. Position a flat container or dish under the drain hole. 
Do not allow the water to drip continuously into the container, as it
might easily overflow. 
3. Remove the drain knob & rubber plug from the drain hole. The 
condensed water will drain out automatically. 
4. When the container is almost full, replace the rubber plug into 
the drain hole to stop the water. Empty the container. 
5.  Repeat steps 2, 3 & 4 until all the condensed water is emptied.
6.  Once all the condensed water has been removed, replace the 
rubber plug into the drain hole firmly. The Full Water indicator 
should be off now. 
7.  Replace the drain knob. 
* Do not allow the water to drip continuously into the  tray, as it 
may easily overflow. 
 
By Water Tube (Continuous Drainage) 
1. Remove the drain knob and rubber plug and keep them for 
future use. 
2. Use Teflon tape to cover threading on spout, making a flat 
surface for the hose. This will prevent leakage. 
3. Connect a suitable water tube (of 3/4" internal diameter - 
supplied) to the water hole. The condensed water will drain out 
automatically. 
4. If you want to extend the water tube you can connect it with 
another tube (outside diameter ¾”). 
 
Special Caution for Heating Function!  
1. Install the exhaust pipe securely in order to exhaust 
the cool air to the outside (please see page 6). 
2. You can use the continuous drainage option as described above.
3. The warmer the outside air the more heat will be pumped into 
the room. Working range for heat pump function is 41°F to 81°F. 
When used in room temperatures outside this range the unit may 
not function properly. 
4. While using the heating function during low temperatures, 
sometimes the heating will stop for a while in order to melt the 
internal frost. When this occurs, just wait for heating to resume. 
This is normal for compressor operated devices. 
 
 
 
 
Rubber Plug 
Drain Knob 
Water Hole 
 
Rubber Plug 
Drain Knob 
 
 
Drain Pipe 
riginal Water Tube 
Extended Water Tube 
(OD: 3/4") 
O
z
z
63 lbs
66 lbs