Trane PTAC-SVX01C-EN User Manual

Page of 52
10
PTAC-SVX01C-EN
Installation
WARNING
Live Electrical Components!
During installation, testing, servicing 
and troubleshooting of this product, 
it may be necessary to work with live 
electrical components. Have a 
qualified licensed electrician or other 
individual who has been properly 
trained in handling live electrical 
components perform these tasks. 
Failure to follow all electrical safety 
precautions when exposed to live 
electrical components could result in 
death or serious injury. 
WARNING            
Fire Hazard!
Do not use an extension cord with 
this unit. Doing so may cause a fire.
CAUTION
Use Copper Conductors Only! 
Unit terminals are not designed to 
accept other types of conductors. 
Failure to use copper conductors 
may result in equipment damage. 
Electrical Requirements
The PTAC can be powered by a 
power cord connected to a receptacle 
in the wall or in a subbase. It can also 
be connected directly to the building 
supply wires with a hard wire kit.
For U.S. approval, 265V units must 
have a permanent wiring connection. 
This requirement can be met either 
by supplying a subbase for 
concealed cord connection or by 
direct wiring with the hard wire kit.
The power cord measures 60 inches, 
with 56 inches usable from the point 
where the cord exits the unit cabinet 
and the attached plug. 
Installation