York TCGD12 THRU 60 User Manual

Page of 18
400034-YTG-B-0708
Johnson Controls Unitary Products
3
Additional R-22 Charge / Orifice Size for Various Matched Systems
Outdoor Unit 
TCGD12
S21S2(H)
TCGD18
S21S2(H)
TCGD24
S21S2(H)
TCGD30
S21S2(H)
TCGD36
S21S2(H)
TCGD42
S21S2(H)
TCGD48
S21S2(H)
TCGD60
S21S2
Required Orifice or TXV 
1,2
0.041 / 2A 
0.052 / 2A  0.059 / 0.061 / 2A  0.065 / 2A 
0.073 / 2A 
0.081 / 2C 
0.084 / 2C 
0.096 / 2C
Factory R-22 Charge, lbs-oz
3 - 2
3 - 0
3 - 13
3 - 7
3 - 15
4 - 2
4 - 5
5 - 4
Indoor Coil
3,4
Additional Charge, Oz
FC/MC/PC/UC18A2A 
FC/MC/PC/UC18B2A 
FC/MC/PC/UC24A2A 
FC/MC/PC/UC24B2A 
FC/MC/PC32A2A
+3 
+4 
FC/MC/PC35B2A 
+3 
+4 
FC/MC/PC35C2A 
+3 
+4 
FC/MC/PC/UC36A2A 
FC/MC/PC/UC36B2A 
FC/MC/PC/UC36C2A 
FC/MC/PC37A2A –
+7
+12
+4
FC/MC/PC43B2C 
FC/MC/PC43C2C 
FC/MC/PC/UC48C2C –
+5 
+2 
FC/MC/PC/UC48D2C –
+5 
+2 
FC/MC62D2C 
HC18A2A 
0  –
HC30A2A 
0  –
HC36B2A 
+3
+4 
HC42C2C –
+12 
+4 
AHP18B2A 
0 0 
AHP24B2A
0
AHP30B2A 
+3  +4 
AHP36C2A –
+12
+4 
AHP42C2C 
0 –
AHP/SHP60D2C 
AV24B2A 
+2 –
AV36C2A –
+7 
+12 
+4 
AV/SV48D2C 
0  –
FC/MC/PC/UC18A3X 
41  +  0 
52  +  0 
FC/MC/PC/UC18B3X 
41  +  0 
52  +  0 
FC/MC/PC/UC24A3X 
52  +  2 
FC/MC/PC/UC24B3X 
52  +  2 
FC/MC/PC32A3X
61  +  3 
65  +  4 
FC/MC/PC35B3X 
61  +  3 
65  +  4 
FC/MC/PC35C3X 
61  +  3 
65  +  4 
FC/MC/PC/UC36A3X 
59  +  0 
FC/MC/PC/UC36B3X 
59  +  0 
FC/MC/PC/UC36C3X 
59  +  0 
FC/MC/PC37A3X
61 + 7 
65 + 12 
73 + 4 
FC/MC/PC43B3X 
61 + 7 
65 + 12 
73 + 4 
81 + 0 
FC/MC/PC43C3X 
61 + 7 
65 + 12 
73 + 4 
81 + 0 
FC/MC/PC/UC48C3X 
73 + 4 
81 + 5 
84 + 2 
FC/MC/PC/UC48D3X 
73 + 4 
81 + 5 
84 + 2 
FC/MC62D3X 
96  +  0 
HC18A3X 
41  +  0 
52  +  0 
HC30A3X 
59  +  0 
HC36B3X 
61  +  3
65  +  4 
HC42C3X 
61 + 7
65 + 12 
73 + 4 
81 + 0 
For Notes See Page 4.