TABLE 18: ELECTRICAL DATA DM150 (12-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
3
5
3
5
3
5
3
5
3
5
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP HP HP HP
None
--
--
62.9 68.1 68.4 73.6 80 80 80 90
2TP04521825
13.5
37.5
62.9 68.1 68.4 73.8 80 80 80 90
2TP04522425
18
50.0
76.1 82.6 83.0 89.5 80 90 90 90
2TP04523625
25.5
70.8 102.1 108.6 109.0 115.5 110 110 110 125
2TP04525425 40.6
112.7 154.5 161.0 161.4 167.9 175 175 175 175
None
--
--
62.9 68.1 68.4 73.6 80 80 80 90
2TP04521825
18
43.3
67.8 74.3 74.6 81.1 80 80 80 90
2TP04522425
24
57.7
85.8 92.3 92.7 99.2 90 100 100 100
2TP04523625
34
81.8 115.9 122.4 122.7 129.2 125 125 125 150
2TP04525425
129.9 143.5 150.0 150.4 156.9 175 175 175 175
None
--
--
  27.4   30.2   29.6   32.4   35   35   35   40
2TP04521846
18
22.6   33.7   37.2   36.4   39.9   35   40   40   40
2TP04522446
24
30.1   42.7   46.2   45.5   49   45   50   50   50
2TP04523646
34
42.7   57.7   61.2   60.5   64   60   70   70   70
2TP04525446 
54
67.8
 71.6  75.1  74.3  77.8  80  90  80  90
None
--
--
  21.8   23.7   23.6   25.5   25   30   30   30
2TP04521858
18
18.1   26.8   29.2   29   31.4   30   30   30   35
2TP04522458
24
24.1
  34   36.4   36.2   38.6   35   40   40   40
2TP04523658
34
34.1
  46   48.4   48.3   50.6   50   50   50   60
2TP04525458 
54
54.2
 57.1  59.5  59.3  61.7  70  70  70  70
*
Maximum HACR breaker of the same AMP size is applicable.
4.1
6.0
1.8
0.0
575
6.7
60.0
1.3
5.3
8.1
2.2
0.0
460
8.4
73.0
1.6
0.0
230
20.0
146.0
3.5
10.9 16.1
5.5
0.0
Max 
Fuse 
Size 
w/Power 
FLA
FLA
208
20.0
146.0
3.5
10.9 16.1
5.5
Heater 
Amps
Min. Circuit 
Ampacity 
(Amps)
MCA 
w/Power 
Exhaust 
(Amps)
Max 
Fuse* 
Size 
(Amps)
Pwr 
Exh 
Motor
Pwr 
Conv 
Outlet
Electric Heater 
Model No.
Actual 
KW
Voltage
Compressors
OD Fan 
Motors
Supply 
Blower 
Motor FLA
54
TABLE 19: ELECTRICAL DATA DM150 (12-1/2 TON) STD EFFICIENCY W/PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
3
5
3
5
3
5
3
5
3
5
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
72.9
78.1
78.4
83.6
90 90 90 100
2TP04521825
13.5
37.5
73.0
79.5
79.8
86.3
90 90 90 100
2TP04522425
18
50.0
88.6
95.1
95.5 102.0 90 100 100 110
2TP04523625
25.5
70.8
114.6 121.1 121.5 128.0 125 125 125 150
2TP04525425 40.6
112.7 167.0 173.5 173.9 180.4 175 175 175 200
None
--
--
72.9
78.1
78.4
83.6
90 90 90 100
2TP04521825
18
43.3
80.3
86.8
87.1
93.6
90 90 90 100
2TP04522425
24
57.7
98.3 104.8 105.2 111.7 100 110 110 125
2TP04523625
34
81.8
128.4 134.9 135.2 141.7 150 150 150 150
2TP04525425
129.9 156.0 162.5 162.9 169.4 175 175 175 175
None
--
--
  32.4   35.2   34.6   37.4   40   40   40   45
2TP04521846
18
22.6
  39.9   43.4   42.7   46.2   40   45   45   50
2TP04522446
24
30.1
  49   52.5   51.7   55.2   50   60   60   60
2TP04523646
34
42.7
  64   67.5   66.7   70.2   70   70   70   80
2TP04525446 
54
67.8
 77.8  81.3  80.6  84.1  90  90  90  90
None
--
--
  25.8   27.7   27.6   29.5   30   30   30   35
2TP04521858
18
18.1
  31.8   34.2   34   36.4   35   35   35   40
2TP04522458
24
24.1
  39   41.4   41.2   43.6   40   45   45   45
2TP04523658
34
34.1
  51   53.4   53.3   55.6   60   60   60   60
2TP04525458 
54
54.2
 62.1  64.5  64.3  66.7  70  70  70  70
*
Maximum HACR breaker of the same AMP size is applicable.
4.1
6.0
1.8
4.0
575
6.7
60.0
1.3
5.3
8.1
2.2
5.0
460
8.4
73.0
1.6
10.9 16.1
5.5
10.0
230
20.0
146.0
3.5
FLA
FLA
208
20.0
146.0
3.5
10.9 16.1
5.5
10.0
Min. Circuit 
Ampacity 
(Amps)
MCA 
w/Power 
Exhaust 
(Amps)
Max 
Fuse* 
Size 
(Amps)
Max 
Fuse 
Size 
w/Power 
Voltage
Compressors
OD Fan 
Motors
Supply 
Blower 
Motor FLA
Pwr 
Exh 
Motor
Pwr 
Conv 
Outlet
Electric Heater 
Model No.
Actual 
KW
Heater 
Amps
54
TABLE 20:  ELECTRIC HEAT MULTIPLIERS
VOLTAGE
kW Cap. Multiplier
NOMINAL
RATING
240
208
0.75
230
0.92
480
460
0.92
600
575
0.92