York LY8S User Manual

Page of 8
036-21618-003 Rev. A (1205)
Unitary Products Group
3
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
RATINGS & PHYSICAL / ELECTRICAL DATA - UPFLOW MODELS
Models
Input
Output
Cabinet Width
Nominal
Airflow
Total Unit Amps
AFUE
Air Temp. Rise
MBH
MBH
In.
CFM
%
°F
(G,L)Y8S040A12UH11
40
32
14-1/2
1200
9.0
80.0
25-55
(G,L)Y8S060A12UH11
60
48
14-1/2
1200
9.0
80.0
25-55
(G,L)Y8S080A12UH11
80
64
14-1/2
1200
9.0
80.0
35-65
(G,L)Y8S080B16UH11
80
64
17-1/2
1600
12.0
80.0
25-55
GY8S080C22UH11
LY8S080C20UH11
80
64
21
2200
14.0
80.0
25-55
(G,L)Y8S100B12UH11
100
80
17-1/2
1200
12.0
80.0
40-70
(G,L)Y8S100B16UH11
100
80
17-1/2
1600
12.0
80.0
35-65
(G,L)Y8S100C20UH11
100
80
21
2000
14.0
80.0
25-55
GY8S115C16UH11
115
92
21
1600
12.0
80.0
35-65
(G,L)Y8S115C20UH11
115
92
21
2000
14.0
80.0
30-60
(G,L)Y8S130D20UH11
130
104
24-1/2
2000
14.0
80.0
35-65
Models
Max. Outlet 
Air Temp
Blower
Blower Size
Max 
Over-Current 
Protect
Min. wire Size 
(awg) @ 75 ft 
one way
Operation
WGT.
°F
Hp
Amps
In.
LBS
(G,L)Y8S040A12UH11
155
1/2
7.1
10 x 8
20
14
105
(G,L)Y8S060A12UH11
155
1/2
7.1
10 x 8
20
14
110
(G,L)Y8S080A12UH11
170
1/2
7.1
10 x 8
20
14
117
(G,L)Y8S080B16UH11
155
3/4
11.5
11 x 8
20
14
126
GY8S080C22UH11
LY8S080C20UH11
165
1.0
14.0
11 x 11
20
12
140
(G,L)Y8S100B12UH11
170
1/2
7.1
10 x 8
20
14
128
(G,L)Y8S100B16UH11
165
3/4
11.5
11 x 8
20
14
134
(G,L)Y8S100C20UH11
155
1.0
14.0
11 x 11
20
12
145
GY8S115C16UH11
170
3/4
11.5
10 x 10
20
14
145
(G,L)Y8S115C20UH11
170
1.0
14.0
11 x 11
20
12
147
(G,L)Y8S130D20UH11
165
1.0
14.0
11 x 11
20
12
158