AIR FLOW DATA
HIGH / LOW SPEED COOLING AND HEAT PUMP CFM
060B12
080B12
Jumper Settings
High
Low
High
Low
COOL Tap
ADJ Tap*
1343
865
1320
882
A
B
1116
727
1093
755
B
B
1235
791
1203
810
A
A
1026
661
1001
693
B
A
1079
709
1080
730
A
C
889
590
880
641
C
B
900
599
910
642
B
C
787
531
803
585
D
B
814
542
836
597
C
A
712
490
738
557
D
A
725
499
749
561
C
C
641
456
682
529
D
C
080C16
100C16
Jumper Settings
High
Low
High
Low
COOL Tap
ADJ Tap*
1787
1171
1818
1192
A
B
1503
987
1545
1030
B
B
1620
1053
1661
1083
A
A
1405
914
1427
936
B
A
1462
964
1497
991
A
C
1217
785
1234
819
C
B
1245
818
1265
832
B
C
940
608
977
648
D
B
1091
702
1116
728
C
A
852
551
884
572
D
A
983
626
1019
666
C
C
764
544
791
519
D
C
100C20
120D20
Jumper Settings
High
Low
High
Low
COOL Tap
ADJ Tap*
2019
1290
2006
1397
A
B
1790
1174
1687
1131
B
B
1818
1195
1845
1282
A
A
1630
1068
1552
1050
B
A
1649
1082
1694
1157
A
C
1269
848
1502
1011
C
B
1432
956
1400
944
B
C
1078
704
1365
922
D
B
1169
770
1364
931
C
A
986
638
1232
808
D
A
1062
685
1225
808
C
C
866
576
1117
718
D
C
HIGH / LOW HEAT CFM
060B12
80B12
Jumper Settings
High
Low
High
Low
HEAT Tap
ADJ Tap*
1364
843
1433
945
A
Any
1253
745
1320
887
B
Any
1102
660
1223
840
C
Any
1014
607
1134
768
D
Any
80C16
100C16
Jumper Settings
High
Low
High
Low
HEAT Tap
ADJ Tap*
1684
1095
1795
1171
A
Any
1542
1011
1585
1047
B
Any
1426
927
1420
929
C
Any
1289
832
1201
785
D
Any
100C20
120D20
Jumper Settings
High
Low
High
Low
HEAT Tap
ADJ Tap*
2194
1417
1937
1323
A
Any
1999
1290
1757
1199
B
Any
1799
1182
1594
1062
C
Any
1614
1062
1429
957
D
Any
All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. 
static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static 
pressure is not recommended. 
NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air clean-
ers. Consult the instructions for the electronic air cleaner for further details.
* The ADJ “D” tap should not be used.