York DNP036 User Manual

Page of 36
 036-21366-007-A-1205
4
Unitary Products Group
FAN SYSTEM - All 2-1/2, 3, 3-1/2 and 4 ton models operate 
over a wide range of design conditions with a constant CFM, 
electrically commutated (ECM) fan motor. These units easily 
match all types of applications and provide greater on site 
flexibility to match comfort requirement. These models have 2 
cooling speeds and a single heating speed. The cooling 
speed is factory set and can be field adjusted to a second 
speed. The heating speed is factory set to maintain mid point 
rise at the units heating input. It cannot be field adjusted. This 
allows maximum comfort conditions.
Two ton models operate over a wide range of design condi-
tions with a 3-speed direct-drive fan motor. These single 
phase models have the Comfort-Match system that allows 
different speed taps for heating or cooling operations.
SIMPLE CONTROL CIRCUIT - A low voltage printed circuit 
board contains a diagnostic indicator light and a low voltage 
terminal strip. An additional set of pin connectors is also pro-
vided to simplify the field interface of external controls. Mate-
n-lock plug connectors are used. The electrical control box is 
not located in the compressor compartment. The controls are 
mounted on a Control-Tilt control panel to allow the access 
cover to be removed for trouble shooting and maintenance 
without affecting the normal system operating pressures. All 
wiring internal to the unit is color/number coded.
PROTECTED COMPRESSOR - The compressor is internally 
protected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high pressure 
relief valve and a temperature sensor which protect the com-
pressor if undesirable operating conditions occur.
EXCLUSIVE COIL DESIGN - Grooved copper tubes and 
enhanced aluminum fin construction improves heat transfer 
for maximum efficiency and durability.
HEAT EXCHANGERS - Are corrosion-resistant, aluminized-
steel tubular construction to provide long-life, trouble-free 
operation. The unique blow-through design also assures that 
condensate does not collect in humid areas when in the cool-
ing cycle. This adds to longer heat exchanger life and higher 
long term efficiencies.
POST PURGE INDUCED DRAFT COMBUSTION - Exhausts 
combustion products from the heat exchanger upon comple-
tion of the heating cycle to prolong the heat exchanger life.
SELF DIAGNOSTIC FAN CONTROL MODULE - Due to this 
self diagnostic control, less on site time is required to trouble 
shoot these units.
HOT SURFACE TO PILOT IGNITION - Provides faster heat 
delivery. This ignition is highly reliable, durable and elimi-
nates nuisance lockouts. Also assures starts in damp condi-
tions.
MULTI PORT IN-SHOT BURNERS - No field adjustment is 
required to mix the air and gas. These burners are con-
structed of high-grade corrosion-resistant, aluminized-steel.
LOW MAINTENANCE - Long life, permanently lubricated 
condenser and evaporator fan motor bearings need no 
annual maintenance adding greater reliability to the unit. 
Blower assembly can be easily cleaned by the unique Slip- 
Track slide-out blower assembly.
SECURED SERVICE ACCESS PORTS - Protected, exter-
nally mounted, re-usable service access ports are provided 
on both the high and low lines for ease of evacuating and 
charging the system. No final field mounting required.
EASY SERVICE ACCESS - A large, single panel covers the 
electrical and gas controls makes servicing easy. The blower 
compartment has an additional large panel with a built-in 
handle tab. Removing this panel will allow the blower assem-
bly to slide-out for easy removal for maintenance and ease of 
trouble shooting.
REPLACEMENT PARTS - The installer requires no special 
training to replace any of the components of these units and 
does not need to maintain an inventory of unique parts. 
SYSTEM INTEGRATION - Each unit has the internal ability 
to integrate an electronic air cleaner or humidifier to work in 
conjunction with the base unit.
FIELD-INSTALLED ACCESSORIES
LOW NOx KIT - Kit includes all the necessary hardware and 
instructions to field convert units to reduce emissions to less 
than 40 nanogram per Joule. California requirement on single 
phase models only.
PROPANE CONVERSION KIT - Kit includes burner orifices, 
gas valve conversion and installation instructions necessary 
to field convert unit from natural gas to propane.
HIGH ALTITUDE CONVERSION KIT (Natural Gas/Propane) 
- Kit includes all necessary labels and instructions to field 
alter units with natural gas/propane for installations above 
2000 feet. Burner orifices must be obtained from Source 1 
Parts. Propane Conversion Kit must be obtained separately.
ECONOMIZER DOWN DISCHARGE / SUPPLY KIT - Modu-
lating integrated economizer provides simultaneous opera-
tion between the mechanical cooling and economizer 
operation. Independent blade design insures proper control 
and less than 1% leak rate. Includes hood and mesh bird 
screen filter integrated into the hood, dry bulb sensor and 
relief damper. Separate field accessories of single enthalpy 
and dual enthalpy are also available. A built-in barometric 
relief of 25% is provided.
SINGLE ENTHALPY SENSOR - Sensor replaces dry bulb 
sensor standard in economizer kit. Provides improved econo-
mizer operation by sensing the dry bulb temperature from 
outdoors plus the enthalpy content of the outdoor air.
DUAL ENTHALPY SENSOR - Additional sensor to single 
enthalpy sensor. Sensor senses both the return air tempera-
ture dry bulb and humidity in conjunction with the single