NOTE:All gas units are two-stage heating.
First stage is 50% of total.
S.S.E. = Steady State Efficiency (80%) - output divided by input.
TABLE 1: SOUND POWER RATING
1
UNIT
SIZE
CFM
ESP
BLOWER
SOUND POWER (db 10
-12
 Watts)
Octave Band Centerline Frequency (Hz)
SWL
dB(A)
dB(A)
@
10Ft.
2
IWG
RPM
BHP
63
125
250
500
1,000
2,000
4,000
8,000
WR180
6,000
1.00
1,080
4.60
99
99
89
82
84
77
72
67
89
56
WR240
8,000
1.00
1,120
6.65
102
102
92
85
87
80
75
70
92
59
WR300
10,000
1.30
1160
12.5
108
108
98
91
93
86
81
76
98
65
1. These values have been accessed using a model of sound propagation from a point source into the hemispheric\free field.  The dBA 
values provided are to be used for reference only.  Calculation of dBA values cover matters of system design and the fan manufacture 
has no way of knowing the details of each system.  This constitutes and expectation to any specification or guarantee requiring a dBA 
value or sound data in any other form than sound power level ratings.
2. At a distance of 10 feet from the blower.
TABLE 2: CAPACITY RATINGS - (ARI 360)
1
1. Certified in accordance with the Unitary Large Equipment 
certification program which is based on ARI Standard 340/
360.
MODEL
MBH
EER
2
2. EER = Energy Efficiency Ratio at full load - the cooling 
capacity in Btu’s per hour (Btuh) divided by the power input in 
watts, expressed in Btuh per watt (Btuh/watt).
IPLV
3
3. IPLV = Integrated Part Load Value.
COOLING ONLY
WR180C/E00
180
11.9
12.7
WR240C/E00
240
11.0
11.3
WR300C/E00
300
10.0
10.6
COOLING WITH GAS HEAT
WR180N/S
180
11.9
12.7
WR240N/S
240
11.0
11.3
WR300N/S
300
10.0
10.6
COOLING WITH ELECTRIC HEAT
WR180E18
180
11.9
12.7
WR180E36
180
11.9
12.7
WR180E54
178
11.7
12.5
WR180E72
178
11.7
12.5
WR240E18
240
11.0
11.3
WR240E36
240
11.0
11.3
WR240E54
238
10.8
11.1
WR240E72
238
10.8
11.1
WR300E18
300
10.0
10.6
WR300E36
300
10.0
10.6
WR300E54
298
9.8
10.4
WR300E72
298
9.8
10.4
TABLE 3: GAS HEAT RATINGS
MODEL
MBH INPUT
MBH OUTPUT
WR180N/S24
300
240
WR180N/S32
400
320
WR240N/S24
300
240
WR240N/S32
400
320
WR300N/S24
300
240
WR300N/S32
400
320
For units with VFD and electric or gas heat, the
speed of the indoor blower motor continues to
be controlled by duct static pressure via the
VAV control board.
If there are VAV boxes present in the duct sys-
tem, the boxes must be driven to the full-open
position using a customer-supplied power
source to assure adequate airflow across elec-
tric heating elements or gas heat exchanger
tubes.