Fedders CH42ACD1VF User Manual

Page of 6
Split System Heat Pump
4
Specifications subject to change without notice.
LINE SET LENGTH AND SIZE
BTUH
SUCTION LINE SIZES 
LIQUID LINE SIZES
15 ft.
25 ft.
50 ft.
75 ft.
15 ft.
25 ft.
50 ft.
75 ft.
18
3/4
3/4
3/4
3/4
3/8
3/8
3/8
3/8
24
3/4
3/4
3/4
3/4
3/8
3/8
3/8
3/8
30
3/4
7/8
7/8
7/8
3/8
3/8
3/8
3/8
36
3/4
7/8
7/8
7/8
3/8
3/8
3/8
3/8
42
7/8
7/8
7/8
7/8
3/8
3/8
3/8
1/2
48
1 1/8
1 1/8
1 1/8
1 1/8
3/8
3/8
3/8
1/2
60
1 1/8
1 1/8
1 1/8
1 1/8
3/8
3/8
3/8
1/2
Recommended liquid & suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and 
15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied
by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet 
vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.)
Note: See unit installation instructions for proper installation.
COOLING PERFORMANCE DATA
OUTDOOR
UNIT 
MODEL
AIR
HANDLER
RATINGS AT STANDARD CONDITIONS
COOLING DATA AT EXTENDED OUTDOOR AMBIENTS F.M.B.T.U.H.
BTUH
SEER*
CFM
80
85
90
95
100
105
110
115
CH18ABD1VF
AFPB24A1
18,000
13
650
TOTAL
19,450
18,900
18,450
18,000
17,650
17,200
16,750
16,400
SENSIBLE
15,250
14,950
14,600
14,200
14,050
13,800
13,500
13,250
CH24ACD1VF
AFPB24B1
24,000
13
840
TOTAL
25,800
25,150
24,600
24,000
23,450
22,900
22,350
21,950
SENSIBLE
19,900
19,500
19,050
18,700
18,450
18,000
17,650
17,300
CH30ACD1VF
AFPB36A1
28,000
13
1,000
TOTAL
30,050
29,450
28,750
28,000
27,200
26,550
25,800
25,250
SENSIBLE
23,100
22,600
22,050
21,700
21,450
21,050
20,800
20,550
CH36ACD1VF
AFPB36A1
34,000
13
1,200
TOTAL
36,350
35,500
34,800
34,000
33,250
32,550
31,700
30,950
SENSIBLE
28,300
27,850
27,650
27,250
26,950
26,750
26,350
26,050
CH42ACD1VF
AFPC48A1
40,000
13
1,350
TOTAL
42,700
42,550
40,950
40,000
39,000
38,000
37,400
36,800
SENSIBLE
33,250
32,900
32,100
31,500
30,550
29,600
28,450
27,600
CH48ACD1VF
AFPC48B1
46,000
13
1,550
TOTAL
49,300
48,150
46,950
46,000
44,850
43,650
42,500
41,400
SENSIBLE
40,950
39,750
38,100
36,000
34,800
33,550
32,350
31,150
CH60ACZ1VF
AZFPC60B1
56,000
13
1,750
TOTAL
60,550
59,000
57,450
56,000
54,300
52,450
51,100
49,850
SENSIBLE
44,550
43,950
43,100
42,350
41,700
40,950
40,500
39,600
*TDR required to obtain SEER rating.