If your system is  an add-on  type, (installed in conjunction  with a  stan-
dard  furnace)  inspect  your  furnace  blower  motor  and  care  for  it  in the
same way.
FILTER CARE
FILTER CARE
FILTER CARE
FILTER CARE
Inspect  the  air  filter(s)  at  least  once  a  month.  If  they  are  dirty,  wash
reusable filters with a mild detergent per manufacturer’s recommenda-
tions. Replace disposable filters with new filters.
Install the clean filters with “air flow” arrow in the same direction as the
air  flow  in  your  duct.  Filters  should  be  clean  to  assure  maximum  effi-
ciency and adequate air circulation. Drapes, furniture or other obstruc-
tions  blocking  your  supply  and  return  air  grilles  will  also  decrease
efficiency.
OUTDOOR UNIT FINISH
OUTDOOR UNIT FINISH
OUTDOOR UNIT FINISH
OUTDOOR UNIT FINISH
If you wish to maintain the finish of the outdoor unit, it can be polished
with  car  wax.  It  is  recommended  the  unit  be  cleaned  with  soap  and
water prior to waxing.
CLEARANCES
CLEARANCES
CLEARANCES
CLEARANCES
The minimum clearances shown below must be maintained should any
patio or yard improvements be done around the outdoor unit.
Top 48”
Sides 12”
Access 24”
POWER INTERRUPTION
POWER INTERRUPTION
POWER INTERRUPTION
POWER INTERRUPTION
When  ice,  snow,  wind  storms,  etc.  disrupt  electrical  power  supply  to
your house, proceed as follows:
Heating Season
1.
Switch thermostat to emergency heat.
NOTE: There will be no heat available until power is re-established.
2.
Leave  on  emergency  heat  for  at  least  8  hours  after  electrical
power is re-established if the power was off more than 8 hours.
3.
Switch thermostat back to heating or auto.
Cooling Season
1.
Switch thermostat to OFF position.
2.
Do not switch to cooling or auto until electrical power has been re-
established for 8 hours if the power was off more than 8 hours.
SERVICE CALLS
SERVICE CALLS
SERVICE CALLS
SERVICE CALLS
There  are  a  few  instances  where  you  can  avoid  unnecessary  service
calls.  (See  Troubleshooting  Guide  above).  Some  models  provide  fault
codes. The flashing light on the system thermostat is capable of provid-
ing you with time  and  money saving information. The  fault  code num-
bers listed can be handled by taking the corrective action indicated. Call
qualified service person if displaying fault code numbers not listed.
PARTS INFORMATION
PARTS INFORMATION
PARTS INFORMATION
PARTS INFORMATION
Replacement  parts  are  available  from  local  contractor/dealers  or  the
nearest distribution center.
TROUBLESHOOTING GUIDE
PROBLEM
CHECK
ACTION TO TAKE
FAULT CODE
No Heat
or
Cooling
1. Thermostat for proper settings.
Set thermostat to proper setting.
-
2. Circuit breakers and fuses.
Reset circuit breakers - Replace blown fuses.
-
3. Check outdoor unit for dirty coil (Cooling).
Clean coil, see “COIL CARE” section.
2
4. Outdoor unit for snow accumulation. (Heating).
Remove loose snow only.
3
5. Indoor unit for dirty filter (Heating).
Clean or replace, see “FILTER CARE” section.
2
6. Emergency heat light status on thermostat.
Check 1 - 5, call qualified service person.
2
Light on = Malfunction
Check 1 - 5, call qualified service person.
-
Light flashing = Malfunction
Check 1 - 5, call qualified service person with fault code.
-
Wet on Floor 
or in Furnace
Condensate drain and “P” trap
Remove blockage, usually mold or fungus.
-