Heatiator BCDV36 User Manual

Page of 28
01-03
7
33606 Rev D
BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
D. FRAMING
Figure  3  shows  a  typical  framing  of  this  appliance  using
combustible materials. Figure 4 shows the mantel heights
for  mantel  projections.  All  required  clearances  to
combustibles  must  be  adhered  to.
CAUTION:
Wear gloves and safety glasses for protection.
Figure 3 - Framing
Figure 4 - Mantel Height
CAUTION:
Provide adequate clearances around the air open-
ings into the combustion chamber and adequate ac-
cessibility clearances for servicing and proper op-
eration.
E. SETTING THE APPLIANCE
This appliance may be placed on a smooth combustible or noncombustible continuous, flat surface. When the appliance
is  installed  directly  on  carpeting,  tile  or  other  combustible  material  other  than  wood  flooring,  the  appliance  shall  be
installed on a metal or wood panel extending the full width and depth of the appliance. Slide the appliance into position
and level the appliance from side-to-side and front-to-back. Shim as necessary.
Secure the appliance by bending out the nailing flanges on each side of the appliance and nail to framing. The nailing
flanges have been positioned 5/8 inch back from the front of the appliance to allow the addition of drywall.
* from base of appliance
WARNING!
To prevent contact with sagging or loose insulation, the appliance must not be installed against vapor barriers or
exposed insulation. Localized overheating could occur and a fire could result.