Monessen Hearth CSDV20SLP User Manual

Page of 44
16
58D6056
CSDV Series Direct Vent Gas Stove
VENTING INSTALLATION 
9Z\x"
(241 mm)
9Z\x"
(241 mm)
Vent Opening for Combustible Walls
Framing Detail
Vent Opening for Noncombustible Wall
7Z\x"
(190 mm)
VO584-100
VO584-100
Vent Opening
2/99   djt
Figure 17 -
Locate Vent Opening on Wall
HOT
FP1955
horizontal vent cap
Vent Cap
Wood Screw
Apply Mastic to 
All Four Sides 
Figure 18 - 
Install Horizontal Vent Cap
FP1955
HOT
FP1956
vinyl siding standoff
Apply Mastic to 
All Four Sides 
Cut Vinyl Siding 
Away to Fit Standoff 
Wood 
Screw
Vent 
Cap
Bolt
Nut
Standoff 
FP1956
Figure 19 -
Install Vinyl Siding Standoff
W
ARNING
Do  not  recess  vent  termination  into  any 
wall. 
This will cause a fire hazard.
5.  Slide the wall thimble over the vent pipe before con-
necting the horizontal run to the vent cap. Figure 20
6.  Carefully move the stove with vent assembly attached 
toward the wall and insert the vent pipe into the hori-
zontal termination. The pipe overlap should be a mini-
mum of 1Z\v" (32 mm). Apply silicone to the outer pipe 
connection.  Fasten  all  vent  connections  with  screws 
provided.
7.  Slide the wall thimble against the interior wall surface 
and attach with screws. Figure 20
FP1957
install firestop
Interior Wall 
Surface 
Decorative 
Wall Thimble 
Horizontal 
Vent Pipe 
Screw
Vent Cap 
(Horizontal 
Termination)
FP1957
Figure 20 - 
Connect Vent Cap with 
Horizontal Vent Pipe
HORIZONTAL TERmINATION 
CONFIGURATION ExAmpLES 
Figures  21  through  23  show  different  configurations  for 
venting and horizontal termination. Each figure includes a 
chart with an example of horizontal maximum and vertical 
minimum  dimensions  taken  from  the  chart  on  Page  14.  
NOTE:  The  horizontal  run  controls  the  mini-
mum  vertical  height  (i.e.  the  longer  the  hori -
zontal  run,  the  higher  the  termination  will  be).  
Follow the chart on Page 14. All horizontal terminations 
require a 1/4" (6 mm) rise per 12" (305 mm) of horizontal 
run.