DFX & DBX Series Vent Free Fireplaces
OPERATING INSTRUCTIONS
MANUAL CONTROL LIGHTING INSTRUCTIONS
1.  STOP! Read the safety information.
.  Make sure the manual shutoff valve is fully open.
3.  This heater is equipped with an ignition device (piezo) which automatically 
lights the pilot.
4.  Refer to Page 22, Figure 23 for the location of the piezo ignitor and control 
knob. Push in gas control knob slightly and turn control knob clockwise 
 
to the OFF position. 
 
NOTE: Knob cannot be turned to OFF unless knob is pushed in slightly. Do 
not force.
5.  Wait 5 minutes to clear out any gas. Then smell for gas, including near the 
floor. If you smell gas STOP! Follow the instructions under “What to Do if You 
Smell Gas”, Page 22. If you do not smell gas, go to the next step.
6.  From OFF position, push in gas control knob slightly and turn counterclock-
wise 
 to the IGN position. Figure 29. Push in and hold control knob for 5 
seconds.
 
NOTE: If you are running the heater for the first time, it will be necessary to 
press in the control knob for 30 seconds to allow air to bleed out of the gas 
piping.
7.  With the control knob pushed in, push and release the piezo ignitor button to 
light the ODS pilot. The pilot is located on the left side of the heater, behind 
the middle log and in front of the back log. If piezo ignitor does not light the 
pilot, refer to “Match Lighting Instructions”, Page 26.
8.  Hold the control knob in for an additional 10 seconds to prevent the ODS pilot 
from shutting off the gas while the thermocouple is warming up.
9.  Release the control knob.
 
•  If the knob does not pop out when released, stop and immediately call your 
service technician or gas supplier.
 
•  If the ODS pilot will not stay lit after several tries, push and turn the gas 
control knob clockwise 
 to OFF and wait 15 seconds. Repeat steps 6 
through 9.
10. Push in control knob and turn counterclockwise 
 to the HIGH setting. At 
this location the control knob will pop out when positioned correctly. The knob 
can now be positioned at any position between HIGH and LOW. Figures 30 
and 31
Rotate
Push
Figure 29 - 
IGN Position
Figure 30 - 
HIGH Position
Rotate
Push
Figure 31 - 
LOW Position
Rotate
W
ARNING
Wait  30  seconds  before  readjusting  the 
heater  when  the  control  knob  has  been 
turned down to a lower setting.
1.  Turn control knob clockwise 
 to OFF position to completely shut off the heater.
.  If applicable: Turn off all electric power to the heater.
TO TURN OFF GAS TO HEATER